3-40 Operations
The All Ships Call is classified in two categories: Safety Call and Urgency
Call.
To send an All Ships Call
1) Press the ALL SHIP key. The message SAFETY appears on the dot
matrix display and the DSC indicator illuminates.
2) Press the SQ UP/DOWN key. The message URGENCY now appears on
the dot matrix display.
3) Make you selection between SAFETY or URGENCY and press the
ENT key to submit. The prompt RECONFIRM is displayed.
4) Press the ENT key to confirm. A prompt appears on the display,
instructing you to press the PTT switch.
5) Press PTT to transmit the call.
The All Ships Call is made on Channel 16. The transmission power is 1W
for a SAFETY Call and 25W for an URGENCY Call.
3.5.26.7 Receiving an All Ships Call
When receiving an All Ships Call, the unit's manner of response depends
on the type of call received.
When an URGENCY call is received, the DSC Distress alert is sounded.
The LCD displays a message that an URGENCY call is being received,
along with the sender's MMSI number, and a prompt to press ENT to
accept or CLR to log the call. The DSC Distress alert and the displayed
message continue until either ENT or CLR is pressed. If ENT is pressed,
the radio switches to Channel 16 in 25W mode and the contents of the
communication are stored in EEPROM. If CLR is pressed, the radio reverts
to the mode before receiving the URGENCY Call and the contents are
stored in memory.
ENT ENT
Alternate by pressing the
SQ UP/DOWN key
RAY230_sect3_3.p65 7/13/2001, 1:42 PM40