Operating Instructions and Installation Instructions
PossiblecausesPossiblesolutions
IncorrectpowerconnectionThepowersupplymaybewiredincorrectly,ensuretheinstallationinstructionshave
beenfollowed.(RefertoChapter4Cablesandconnectionsforcableandconnection
requirements.)
Powersourceinsufcient
Withtheproductunderload,usingamulti-meter,checkthepowersupplyvoltageas
closetotheunitaspossibletoestablishactualvoltagewhenthecurrentisowing.
(RefertoChapter13Technicalspecicationforpowersupplyrequirements.)
SecondstationRaymicHandsetwillnotpowerup
PossiblecausesPossiblesolutions
Handsetnotturnedon
TheoptionalsecondstationhandsetavailablefortheRay60andRay70ispowered
separatelyfromtheBasestation.PressthePowerbuttonlocatedonthetopofthe
Handsettopoweriton.
SoftwareBasestation/Handset
mismatch
TheRaymichandsetandBasestationmustbothberunningcompatiblesoftware,
refertotheRay60/Ray70andRaymicHandsetsoftwarecompatibilitysectionfor
detailsofcompatiblesoftwareversions.
Poor/damaged/insecurecables/
connections
1.CheckthattheBasestationiscorrectlypowered.
2.WiththeHandsetturnedon,tryexingthecableneartotheconnectorstoseeif
thiscausestheHandsettore-boot/loosepower,replaceifnecessary.
3.Checkcableconnectionsaresecure,cleanandfreefromcorrosion,replace
ifnecessary.
84