Installation Manual

Bondedgroundsystem(preferred)
D117 09 -1
1 2 4
3
RFgroundsystem(alternative)
D117 10 -1
1 2 4
3
1.Powercabletoproduct
2.Drain(screen)
3.Bonded(preferred)ornon-bondedRFground.
4.Battery
Implementation
Ifseveralitemsrequiregrounding,theymayrstbeconnected
toasinglelocalpoint(e.g.withinaswitchpanel),withthispoint
connectedviaasingle,appropriately-ratedconductor,totheboat’s
commonground.Thepreferredminimumrequirementforthepath
toground(bondedornon-bonded)isviaaattinnedcopperbraid,
witha30Arating(1/4inch)orgreater.Ifthisisnotpossible,an
equivalentstrandedwireconductormaybeused,ratedasfollows:
forrunsof<1m(3ft),use6mm
2
(#10AWG)orgreater.
forrunsof>1m(3ft),use8mm
2
(#8AWG)orgreater.
Inanygroundingsystem,alwayskeepthelengthofconnecting
braidorwiresasshortaspossible.
Important:DoNOTconnectthisproducttoapositively-grounded
powersystem.
References
ISO10133/13297
BMEAcodeofpractice
NMEA0400
Installation
17