SDS
_____________________________________________________________________________________________
Potassium hydroxide
1310-58-3
Ceiling: 2 mg/m
3
(vacated) Ceiling: 2 mg/m
3
Ceiling: 2 mg/m
3
Cobalt
7440-48-4
TWA: 0.02 mg/m
3
TWA: 0.1 mg/m
3
dust and fume
(vacated) TWA: 0.05 mg/m
3
dust
and fume
IDLH: 20 mg/m
3
dust and fume
TWA: 0.05 mg/m
3
dust and fume
Manganese
7439-96-5
TWA: 0.02 mg/m
3
respirable
fraction
TWA: 0.1 mg/m
3
inhalable
fraction TWA: 0.02 mg/m
3
Mn
TWA: 0.1 mg/m
3
Mn
(vacated) TWA: 1 mg/m
3
fume
(vacated) STEL: 3 mg/m
3
fume
(vacated) Ceiling: 5 mg/m
3
Ceiling: 5 mg/m
3
fume Ceiling: 5
mg/m
3
Mn
IDLH: 500 mg/m
3
TWA: 1 mg/m
3
fume
STEL: 3 mg/m
3
Aluminum
7429-90-5
TWA: 1 mg/m
3
respirable fraction TWA: 15 mg/m
3
total dust
TWA: 5 mg/m
3
respirable fraction
(vacated) TWA: 15 mg/m
3
total
dust
(vacated) TWA: 5 mg/m
3
respirable fraction (vacated)
TWA: 5 mg/m
3
Al Aluminum
TWA: 10 mg/m
3
total dust
TWA: 5 mg/m
3
respirable dust
ACGIH TLV: American Conference of Governmental Industrial Hygienists - Threshold Limit Value OSHA PEL: Occupational Safety and Health
Administration - Permissible Exposure Limits Immediately Dangerous to Life or Health
Other Exposure Guidelines
Vacated limits revoked by the Court of Appeals decision in AFL-CIO v. OSHA, 965 F.2d 962
(11th Cir., 1992) See section 15 for national exposure control parameters
Appropriate engineering controls
Engineering Measures
Showers
Eyewash stations
Ventilation systems
Individual protection measures, such as personal protective equipment
Eye/Face Protection
Face protection shield.
Skin and Body Protection
Wear protective gloves and protective clothing. Long sleeved clothing. Chemical resistant
apron. Impervious gloves.
Respiratory Protection
No protective equipment is needed under normal use conditions. If exposure limits are
exceeded or irritation is experienced, ventilation and evacuation may be required.
Hygiene Measures
Handle in accordance with good industrial hygiene and safety practice. Avoid contact with
skin, eyes or clothing. Wear suitable gloves and eye/face protection. Do not eat, drink or
smoke when using this product. Take off contaminated clothing and wash before reuse.
Contaminated work clothing should not be allowed out of the workplace. Regular cleaning
of equipment, work area and clothing is recommended. Wash hands before breaks and
immediately after handling the product. For environmental protection, remove and wash all
contaminated protective equipment before re-use.
9. PHYSICAL AND CHEMICAL PROPERTIES
Physical and Chemical Properties
Physical State
Solid
_____________________________________________________________________________________________
1103427 - Rayovac NiMH Rechargeable Batteries
None known
Color
Melting / freezing point
No data available
No information available
None known
Revision Date 16-Apr-2015
Boiling point / boiling range
No data available
Odor Threshold
None known
No information available
Flash Point
No data available
Appearance
None known
Solid
Property Values
Odor
Remarks Method
Odorless
Page 6 / 14
pH
No data available