Instructions / Assembly

37
OPERATING INSTRUCTIONS AND SHUTOFF PROCEDURES
MILLIVOLT SYSTEM
(MANUALLY-LIGHTED PILOT)
A. This appliance has a pilot which must be lit
by hand. When lighting the pilot, follow these
instructions exactly.
B. BEFORE LIGHTING, smell all around the ap-
pliance area for gas. Be sure to smell near the
oor because some gas is heavier than air and
will settle on the oor.
WHAT TO DO IF YOU SMELL GAS:
*Do not try to light any appliance.
*Do not touch any electric switch; do not use any
phone in your building.
*Immediately call your gas supplier from a neigh-
bor’s phone. Follow the gas supplier’s instruc-
tions.
*If you cannot reach your gas supplier, call the
re department.
C. Use only your hand to push in or turn the gas
control knob. Never use tools. If the knob will
not push in or turn by hand, do not try to repair
it. Call a qualied service technician. Force or
attempted repair may result in a re or explo-
sion.
D. Do not use this appliance if any part has been
under water. Immediately call a qualied ser-
vice technician to inspect the appliance and to
replace any part of the control system and any
gas control which has been under water.
1. STOP! Read the safety information above.
2. Set the thermostat to the lowest setting.
3. Turn On/O󰀨 switch to the "OFF" position.
4. Remove heater door panel.
5. Push in gas control knob slightly and turn clockwise
to "OFF".
NOTE: Knob cannot be turned from "PILOT" to "OFF"
unless knob is pushed in slightly. Do not force.
6. Wait 5 minutes to clear out any gas. If you then smell
gas, STOP! Follow "B" in the safety information
above. If you don’t smell gas, go to the next step.
7. Locate pilot mounted in the right side panel of the
burner tray.
1. Set the thermostat at the lowest setting.
2. Turn On/O󰀨 switch to the "OFF" setting.
3. Remove heater door panel.
4. Push the gas control knob slightly and turn clockwise
to “OFF”. Do not force
5. Replace heater door panel.
8. Turn gas control knob counter-clockwise to
"PILOT".
9. Place ame to end of pilot tube. Push in control knob
all the way and hold to light pilot. Continue to hold
control knob in for about one minute after the pilot
has lighted, release knob and it will pop up. Pilot
should remain lighted. If it goes out, repeat steps 5
through 9. If knob does not pop up when released,
stop and immediately call your service technician or
gas supplier.
10. Stand to the side of the heater and turn the gas
control knob counter-clockwise to "ON".
11. Replace heater door panel.
12. Turn On/OFF switch to the "ON " position.
13. Set thermostat to the desired setting.
HONEYWELL
MILLIVOLT
GAS VALVE
ROBERTSHAW
MILLIVOLT GAS VALVE
FOR YOUR SAFETY READ BEFORE LIGHTING
LIGHTING INSTRUCTIONS
TO TURN OFF GAS TO APPLIANCE