Models HD101 thru 2342B
Up to 87% thermal efficiency! Raypak’s Hi Delta Key Features Decades of expertise and technological innovations went into creating the Hi Delta boiler, a product that incorporates features sought after by engineers, installers and end-users alike. ● 19 models from 100,000 to 2,340,000 BTUH ● All models indoor/outdoor certified ● Efficiency: In 1948, Raypak introduced the first straight copper finned tube boiler designed with reliability and serviceability in mind.
9 5 8 6 7 4 11 2 1 1. Lightweight Refractory Panels Multi-piece ceramic fiber panels enhance combustion while minimizing heat retention. 2. Fully-enclosed Headers Temperature sensors and lead wires/capillaries are protected from weather, vandalism, and accidental damage during installation and service. 3. Flue Connection Top or back outlet flue connections offer greater installation flexibility. 4.
Sidewall Vent Vertical Venting Category III Category I (Type B) Options SureRackTM Kit The perfect solution for today’s most space challenged equipment rooms. Stacking two Hi Delta 2342 boilers provides over 4.6MMBTU in just over 26 square feet plus clearances. All components (except pumps and PRV’s) are contained inside the cabinet, so there won’t be any gas valves or fans hanging off the unit. The units remain fully serviceable even while racked.
Cold Water Start Cold Water Run Cold Water Solution Options Cold Water Start It is commonly known that prolonged internal condensation will dramatically shorten the life of standard boilers and water heaters. While Raypak boilers and water heaters can operate without harmful condensation at lower inlet water temperatures than the competition, there are still applications that require reliable protection against harmful condensation caused by frequent, extended, cold water startups.
Recovery Rates (GPH) 84% EFFICIENCY (TYPE H) 85% AFUE Hi Delta MBTUH Model Input HD101 HD151 HD201 HD251 HD301 HD401 302B 402B 502B 652B 752B 902B 992B 1262B 1532B 1802B 2002B 2072B 2342B 100 150 199 250 299 399 300 399 500 650 750 900 990 1260 1530 1800 1999 2070 2340 Temperature Rise (°F) 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 1020 1531 2031 2551 3051 4024 3055 4063 5091 6618 7636 9164 10080 12829 15578 18327 20353 21076 23825 510 765 1015 1276 1526 2012 1527 2031 2545 330
MBTUH Output* Ref. Hi Delta MBTUH Dwg. Model Input* pg. 5 2 3 85% AFUE 100 150 199 250 299 399 300 399 500 650 750 900 990 1260 1530 1800 1999 2070 2340 84% BOILER 1 HD101 HD151 HD201 HD251 HD301 HD401 302B 402B 502B 652B 752B 902B 992B 1262B 1532B 1802B 2002Bª 2072B 2342B Type H (Cat. I) 87%† (Cat. II) 85 128 169 213 254 335 252 335 420 546 630 756 832 1058 1285 1512 1679 1739 1966 N/A N/A N/A N/A N/A N/A 261 347 435 566 653 783 861 1096 1331 1566 1739 1801 2036 Dimensions (in.
DRAWING 1 - MODELS HD101-HD401 K FLUE CONNECTION DIA. B OPTIONAL PUMP 8-7/8 H WATER IN LOW VOLTAGE CONNECTIONS SEE PUMP CHART T COMBUSTION AIR DIA.
84% EFFICIENCY (TYPE H) 85% AFUE Hi Delta Model ▼ HD101 HD151 HD201 HD251 HD301 HD401 302B 402B 502B 652B 752B 902B 992B 1262B 1532B 1802B 2002B 2072B 2342B 87% EFFICIENCY (TYPE H) 85% EFFICIENCY (TYPE WH) Hi Delta Model ▼ 8 HD101 HD151 HD201 HD251 HD301 HD401 302B 402B 502B 652B 752B 902B 992B 1262B 1532B 1802B 2002B 2072B 2342B Hi Delta Model ▼ 302BE 402BE 502BE 652BE 752BE 902BE 992BE 1262BE 1532BE 1802BE 2002BE 2072BE 2342BE Flow Rates Minimum Flow Pressure Drops 10°F ⌬T Maximum Flow GPM ⌬P
SAFETIES OPERATING CONTROLS HEAT EXCHANGER Boilers (Type H) GAS TRAIN AIR 302B-902B 992B-2342B N/A N/A N/A N/A N/A N/A (1) N/A N/A N/A N/A N/A N/A (2) (3) N/A N/A (4) (5) (6) N/A N/A (2) (3) N/A N/A (4) (5) (6)