Instructions / Assembly

18
Figure 25. Run Time Indicator
Press the DOWN button. The Fault History displays up to
ten faults in memory. The order of the faults begins with
“Fault Last,” which is the most recent fault, and proceeds
through ten most recent messages in chronological order.
The second line of the display shows the fault message.
If there are no faults in the history buer, the second line
reads All Faults Clear.
Figure 26. Fault History Indicator
5.3.2. Program Button
1. Remove the two screws holding the control cover,
and swing the panel down so the back side of the
board is visible. Locate the Program Mode button
(SW1) as shown in Figure 22. Press and hold the
button for 5-7 seconds until Set Factory Defaults
appears on the display. Release the program button.
2. Press the MENU/SET button sequentially until
the desired program event is reached. There are
5 different events that can be programmed. They
appear in the sequence listed in Figure 27:
Resets board to factory default
settings.
Resets faults in the History File.
Change from Fahrenheit to
Celsius.
SPA setpoint maximum
adjustment.
POOL setpoint maximum
adjustment.
Figure 27. Programmable Events
Set Factory Defaults
Refer to step one above to access the program screen. Set
Factory Defaults should appear on the screen. If it does
not, press the MENU/SET button until it appears on the
digital display. Press and hold both UP and DOWN buttons
for 5-7 seconds until Defaults Set appears. This operation
resets the operating program to its factory default values.
Both the POOL and SPA setpoints will revert to 65°F (18°C)
and both POOL and SPA maximum temperature settings
will be 104°F (40°C). The Control Lockout PIN will be
cleared and the control will resume normal operation.
Clear Faults
Refer to step one above to access the program screen.
Press the MENU/SET button until Clear Faults appears
on the digital display. Press and hold both UP and DOWN
buttons for 5-7 seconds until Faults Cleared appears. This
operation resets the Fault History le to “0” and clears all
the stored faults.
Fahrenheit or Celsius
Refer to step one above to access the program screen.
Press the MENU/SET button until Fahrenheit or Celsius
appears on the digital display. The UP or DOWN buttons
will select Fahrenheit or Celsius on the temperature
display. Choose the desired temperature scale.
Spa Max Temp – Spa Set Point Maximum
Adjustment
Refer to step one above to access the program screen.
Press the MENU/SET button until Spa Max Temp appears
on the digital display. Using the UP and DOWN buttons
will change the Maximum Temperature Setting to your
desired value. The control can be set for a maximum of
107°F (42°C).
Pool Max Temp – Pool Set Point Maximum
Adjustment
Refer to step one above access into the program screen.
Press the MENU/SET button until Pool Max Temp appears
on the digital display. Using the UP and DOWN buttons
will change the Maximum Temperature Setting to your
desired value. The control can be set for a maximum of
107°F (42°C).
5.3.3. Control Lockout
The heater is equipped with a Control Lockout feature
to prevent unauthorized tampering or adjustment of the
control settings. To lock out the controls, press the DOWN
button and MENU/SET button for 5 seconds. Choose a
three digit PIN, using the UP and DOWN buttons to select
the digits and the MENU/SET button to lock in selections.
Conrm your selection and record your PIN.
To unlock the controls, press any button to bring up the
Enter PIN menu. Enter the PIN that was used to lock the
control. Note that power cycling will not clear the lockout.
Successfully unlocking the control will display “Lockout
Cleared. Failure to enter the correct PIN will display
“Invalid PIN.
In the event that the user-selected PIN is lost or does not
clear the Control Lockout, use the Program Button to Set
Factory Defaults. This will clear the PIN and allow normal
operation and selection of a new PIN if desired.