User's Manual

Table Of Contents
Synapsis Radar
with Nautoscan NX Pedestal
Operator Manual
4265.DOC020102
2-22
Edition July 2015
Operator controls
Text identifier
Radar Transceiver Status.
Example;
This Radar is connected to Transceiver XCVR2.
This Radar is used as X-BAND Radar.
This Radar is used as MASTER under X-BAND
condition.
2.2.1.1 System Configuration Diagram
The system configuration diagram displays the actual setup and can be used to
connect the own Display (A, B, C..) to any Transceiver (1 MK2, 2 MK2 …..) as
Master or Slave. The connection will be realized per link.
A line symbol between the display and the transceiver shows the link.
A dashed line indicates a connection link in progress.
A continuous line indicates an active link.
The operator can choose between the application Display (A, B, ... ) in Master
mode or Slave mode. The Transceiver symbols are equipped with two
connection points.
M for Master mode
S for Slave mode
Within a Radar system each Transceiver can only be controlled by one display
in Master mode at the same time. The other display can control the transceiver
in Slave Mode only.
Master control.
When M is selected, the transceiver will respond if no other display is already
Master.
Master control allows Pulse length Control, PMU operation, and Sector
Blanking Control.
Transceiver Warm Up time may appear, the total POWER ON time of the
scanner, and MAG SEND TIME.