User's Manual
Table Of Contents
- 0 General
- 1 BASIS SETTINGS TO USE THIS RADAR
- 2 OPERATING INSTRUCTION
- 2.1 Radar Operation
- 2.2 Set to Operation
- 2.3 Display Organization and Submenu Structure
- 2.3.1 Sensitivity Controls
- 2.3.1.1 Gain and Clutter Processing
- 2.3.1.2 Tune
- 2.3.1.3 Gain
- 2.3.1.4 Sea
- 2.3.1.5 Rain Rate
- 2.3.1.6 Automatic Clutter Reduction
- 2.3.1.7 Filtering Rain Clouds FTC
- 2.3.1.8 Search and Rescue Transponder SART ON/OFF
- 2.3.1.9 Pulse Width Selection (only available in Master mode)
- 2.3.1.10 Interference Selection IR ON/OFF
- 2.3.1.11 Echo Expansion EXP. ON/OFF
- 2.3.2 Radar Video Displays
- 2.3.3 Radar Video Settings
- 2.3.4 Navigational Elements MAP, PIL, EBL and VRM
- 2.3.5 Cursor Information
- 2.3.6 Cursor in Park Position
- 2.3.7 Information Panel
- 2.3.1 Sensitivity Controls
- 2.4 Select Target Information TGT INFO
- 2.5 Target Menu
- 2.6 Zone Management
- 2.7 Function Menu
- 2.7.1 Select the Backlight Menu Brightness Control and Color Palette
- 2.7.2 Select T-SCE (ON/OFF)
- 2.7.3 Select Route (Option)
- 2.7.4 Select Zoom Menu
- 2.7.5 Select Sector Blanking (ON/OFF)
- 2.7.6 System Clear
- 2.7.7 Performance Monitor (PMU)
- 2.7.8 Magnetron Current
- 2.7.9 Test Alert
- 2.7.10 Senc Menu
- 2.7.11 Chart Info
- 2.8 Chart Radar Function
- 2.9 Select ARPA Trial Manoeuvre
- 2.10 Sea Scout (Option)
- 2.11 Alarm and Warning messages and handling
- 2.12 Working Around the Radar Antenna
- 3 Theory of Operation
- 4 Index
Synapsis Radar
with Nautoscan NX Pedestal
Operator Manual
4265.DOC020102
2-230
Edition July 2015
WARING MESSAGE
a) Problem Description
b) Corrective Action
FIX ACTIVE: SENC
a) Manual SENC Offset
FIX ACTIVE: CHART
a) Manual CHART Offset
PMU TX POWER LOW
a) Transmit power reduced by at least 3dB.
b) Refer to the maintenance section
troubleshooting and repair (change the
Magnetron).
Call Service.
REACHING MAX AUTO
ARPA TARGETS
a) The Radar System automatically
acquired 38 targets.
REACHING MAX MAN
ARPA TARGETS
a) The Operator manually acquired 38
targets.