User's Manual

MASTR III Repeater Calibration Procedure 5/16/2011
Raytheon JPS Communications, Inc. 2-3
8/22/2011
2.1.2 Initial Steps
2.1.2.1 Set the Radio Test Set to analog duplex mode and program to monitor the
frequency of the transmitter.
2.1.2.2 Power up the radio and P25net CC.
2.1.2.3 Launch PCCT and connect to the P25net CC channel.
2.1.3 Radio Tx Calibration
2.1.3.1 In PCCT go to the Configure >Tx window and select Analog Sine Wave
per Figure 2-2. Preset the Tx Gain and Offset Pots to the values shown.
Figure 2-2 Configure Tx Window