P a g e 6 R E V : 1 . 0
7.3 High Temperature Test
Temperature: 60±2℃
Storage time: 96 hours.
Humidity: 50±5% R.H.
After this test the mouse shall be left in room temperature for 1 hour.
Judging Criteria: No functional defect should be found.
7.4 Low Temperature Test
Temperature: -15±2 ℃
Storage time: 96 hours
After this test the mouse shall be left in room temperature for 1 hour.
Judging Criteria: No functional defect should be found.
7.5 Moisture Test
Temperature: 40±2℃
Humidity: 96~95% R.H.
Storage time: 96 hours.
After this test the mouse shall be left in room temperature for 1 hour.
Judging Criteria: No functional defect should be found.
7.6 Heat cycle test
Temperature: -15±2℃ for 1hr and then 60±2℃ for
1hr
Storage time: 3 cycles.
Humidity: 0~90% R.H.
After this test the mouse shall be left in room temperature for 1 hour.
Judging Criteria: No functional defect should be found.
8. Syestem Requirement:
·An available USB port
·IBM-compatible PC or Mac
·Windows 98/SE/ME/2000/XP/Vista/Win7/Win 8/Win 10 Mac OS X(10.2x or
later)