Operation Manual

29
ENGLISH
70V0
POWER OUTPUT
100V70VCOM
70V0 70V0
POWER SUPPLY VOLTAGE CHANGE
IMPORTANT: This manual section is for qualified personnel only.
The following instructions are to be ignored by the user.
Make sure the device is not connected to the mains (unplug the power supply cable).
Remove the lid.
The voltage change
connector is highlighted by
a square.
If the mains voltage is 230 V, set the connector to the 230Vac position (see the
picture 2), according to the PCB indication (looking at the connector front, the
central pin is connected to the right one).
If the mains voltage is 115 V, set the connector to the 115 Vac position (see the
picture 3), according to the PCB indication (looking at the connector front, the
central pin is connected to the left one).
Refit the device lid.
Before connecting the device to the mains, make sure that the fuse (inside the IEC power supply
connector of the rear panel, see 25) is the correct current rating for the mains voltages (read the fuse
indication below the connector).
PICTURE 1
PICTURE 2
PICTURE 3