User's Manual

9
ENGLISH
IMPORTANT NOTES
UNBALANCED CONNECTION: the audio signal can be affected by external interferences
and its level is attenuated of 6 dB (due to its half voltage). Do not use a cable longer than
5m!
6 INPUT SENSITIVITY CONTROL
The input sensitivity can be adjusted through this control (+6 dBu ÷ –6 dBu).
Turn it clockwise to increase the input sensitivity.
The central (0 dBu) and the 2 extreme (+6 dBu, –6 dBu) positions are dented.
IMPORTANT NOTES
Ensure that all studio monitors placed in the same recording studio (/ room) are all set
to the same level.
7 Dip-switches
See the following section ‘Dip-switch settings’
8 USB port reserved for RCF service only.
BASS TILT (A, B dip-switches)
This setting is a low-shelf shaping filter that reduces frequencies below 500 Hz by the
selected amount (OFF, -1dB, -2dB, -4dB).
This filter helps to correct the progressive increase of mid-low and low frequencies due to
resonances in small rooms.
The amount of correction will depend on the size and shape of the room (a bigger correction
for smaller and regular shaped rooms). A large room shall require no correction.
1/4” JACK PLUG
IMPORTANT NOTES
IMPORTANT NOTES
DIP-SWITCH
SETTINGS