Gas Connections
Check gas type use only the type of gas indicated in the rating plate.
Do NOT connect an unregulated gas source to the appliance. You MUST use the
regulator(s) that are available from RCS.
Safe and satisfactory operation depends to a great extent on the proper installation of the
appliance. The installation must comply with the local codes, or in the absence of local codes, with
either the National Fuel Gas Code, ANSI Z223.1 or CAN/CGA B149.1 or 149.2.
Installer supplied manual gas shut-off valve must be installed in an easily accessible location in the
gas supply line ahead of the pressure regulator (4”W.C.).
The outdoor cooking gas appliance and its individual shut-off valve must be disconnected from the
gas supply piping system during any pressure testing of the system at test pressures in excess of
1
/
2
Psi (3.5kPa). Over-pressure will cause the valves to fail!
The supply line must be sized and installed to provide a sufficient supply of gas to meet the
maximum demand of the grill without undue loss of pressure. The sealant used on the threaded
joints of the gas pipe must be a type resistant to the action of LP gases.