Instructions / Assembly

7
(Fig. 5)
1.
2. 3.
(Fig. 1)
Wheninstallingastructuralpostin
afascia(thru)-mountapplication,
besurethatsufficientmounting
structureexiststoreceivepost
attachmentfasteners.
Whenmountingtoastraightface,
threefastenersshouldbeused(Fig.
1).Inaninsidecornerapplication,
fivefastenersshouldbeusedto
maximizestrengthinbothdirections
(Fig2).
Note:
Thru-boltingusing3/8”stainless
steelboltsisrecommendedtoattain
maximumstrengthanddurability.
Ensuringthatthepostisplumbfrom
side-to-sideandattheappropriate
height,clampinplace(Fig.3).
Postsshouldbeinstalledataheight
of36”foranRDIresidentialrailingkit
and42”foranRDIcommercialrailing
kit.
Usingtwostandarddeckscrews,
temporarilysecurethepostinplace
throughthetwosmallerholesinthe
post(Fig.4).
Tip:
IfusingEndurance
®
DeckRail™with
DecorativeCap,pleaserefertothe
instructionbookletincludedinthe
DeckRailkit(orwww.rdirail.com)for
finishedpostheight.
Aftermountinglocationiscon-
firmed,pre-drillforpermanent
mountinghardware(Fig.5).
Usingtheprovidedvinylshims,
plumbthepostandpermanently
securewithatleastthreemounting
fasteners(Fig.6,7).
(Fig. 3)
(Fig. 4)
(Fig. 6)
(Fig. 7)
vinyl
shim
(Fig. 2)