Service manual

E126
Unable to calibrate the sensor for control
of print starting point (LS3).
Letter jam / print start sensor dirty
=> C: remove letters from letter passage (please refer to section removing letter jams of ultimail
operator manual)
=> E: clean/test print start sensor. The value for LS3 in the system info must be between 70-140. (If
the value is 199 or 0, maybe the mainboard is defect) (regulation offset)
E127
The calibration of the cartridges failed
Contact problems /bad cartridge?
Please use the subcode
Cotact problem /Cartridge failer
=> C: exchange cartridge, install again
=> T: run contact test in Service mode
search for your subcode…
see also technical bulletin #1
E127 xx1x xxxx
xxxx xxxx
left cartridge => print voltage to high
=> C: exchange cartridge, install again
=> T: run contact test in Service mode, check temperatur on the cartridge in service mode => cartridge
info
see also technical bulletin #1
E127 xx2x xxxx
xxxx xxxx
left cartridge => low voltage
=> C: exchange cartridge, install again
=> T: run contact test in Service mode, exchange the pen driver board (RDS mover)
E127 xx4x xxxx
xxxx xxxx
left cartridge => contact problem Cotact problem /Cartridge failer
=> C: exchange cartridge, install again
=> T: run contact test in Service mode
search for your subcode…
see also technical bulletin #1
E127 xx8x xxxx
xxxx xxxx
left cartridge => identification error
=>C: install cartridge again, exchange the cartridge
maybe wrong or non FP cartridge?
=>T: run contact test in service mode and clean the contacts
E127 xxx1 xxxx
xxxx xxxx
left cartridge => HP-ASIC to warm
(>125C)
=> C: exchange cartridge, install again
=> T: run contact test in Service mode, exchange the pen driver board (RDS mover)
diagnostic-
code
subcode1
subcode2
diagnostic message remedy
ISS international service support
email: iss@francotyp.com created : 20.11.2007 19:33 Uhr
page 15 Ultimail