AA100 Access Air 100 Air Curtain System
TABLE OF CONTENT Topic Page Disclaimer Serial Number Identification Introduction Product Information Specifications Dimensions Safety Information Installation Procedures Physical Installation Electrical Installation Operations Modes of Operation Maintenance Maintenance Schedule Daily Monthly Yearly Service Troubleshooting Guide (Cause and Effect) Parts Lists Parts List (Description/Part Number) Schematics Electrical Wiring Diagram / Warranty 3 3 3 2 4 4 4 5 7 8 8 8 8 9 9 9 / 11
DISCLAIMER Ready Access Disclaims any Liability for any damage or harm caused to the AA100 Air Curtain, it’s operator or any other equipment however caused if the AA100 Air Curtain is repaired or serviced by anyone other than an authorized service engineer or Contrary to the manufacturers written instruction contained herein.
Product Information SPECIFICATIONS AND PERFORMANCE Model Number Unit Voltage USA Actual Unit Amps AA100 110/120 VAC 60Hz Single Phase 5A Air Velocity High / Low 2000/1800 FPM at Nozzle Dimensions In Inches WxHxD Weight In Shipping Carton See Below 29 lbs Dimensions 12" (305mm) 22" (559mm) 11 - 3/4" (299mm) Figure 1 SAFETY INFORMATION WARNING: To avoid the risk of Fire, Electric Shock or Injury to persons, observe the following: Use this unit only in a manner intended by the manufacturer.
Installation Procedures PHYSICAL INSTALLATION Before you begin installing your Ready Access Air Curtain, you must determine what type of installation will be required. Wood Frame, Masonry Framing, etc. See the illustration below to determine your rough opening size and mounting. Warning: Two people are required for the lifting and installation of the window.
CONFIRM THAT THE CUSTOMER-SUPPLIED FRAME IS MADE TO ACCOMMODATE THE DIMENSIONS AS ILLUSTRATED ABOVE. 1. Unpack AA100 unit from carton and inspect for shipping damage. Contact Ready Access as soon as possible if damage has occurred. (800) 621-5045 2. A rough opening of 22-1/4" (565 mm) W x 12" (305 mm) H must be constructed before installation of AA100 unit. 3. Remove the (4) #2 phillips drive screws from the AA100 unit inside cover. This will allow access into unit once in position of rough opening. 4.
Electrical Installation All power must be connected and wired by a qualified electrician and be in compliance with all state and local building codes. 1. Remove the (4) #2 phillips drive screws from the inside cover. 2. Located in the upper right hand of AA100 unit, will be an electrical entry junction box. Remove cover and expose (1) black wire (HOT), (1) white wire (COMMON) and (1) green wire (GRD). WARNING - Disconnect power at service panel / circuit breaker before installation to AA100 unit.
Initial Window Operation Modes of Operation The AA100 has two modes of operation. Run and Shutdown. Shut Down: The main switch is in the “OFF” position. The unit has no operations. Run The Main switch is in the “ON” position. The unit functions as a “Fly Fan”. If the AA100 does not operate correctly, go to the troubleshooting guide in this manual. If the AA100 still do not operate properly, then call Ready Access at 1-800-621-5045 Each operator must read the operations manual before operating the unit.
SERVICE Issue Probable Cause Resolution No Fan Operation. No power to the unit. Switch does not Illuminate Check / Reset the main circuit breaker or switch. Defective Main Switch. Replace the switch. Switch Option is not operating. Find and correct problem. Defective Blower. Replace the blower. Switch Option is not operating. Find and correct problem. No Fan Operation. Switch Illuminates Normally.
WARRANTY: Ready Access will only accept responsibility for manufacturing defects in the product’s construction and/or materials. Adjustments required during installation are the responsibility of the installer or contractor and will not be covered under warranty. Problems caused by improper installation are the responsibility of the installer or contractor and will not be covered under warranty.
Ready Access, 1815 Arthur Drive, West Chicago, Illinois 60185, Tel: 630-876-7766, Tel: 800-621-5045 Fax: 630-876-7767, Email: ready@ready-access.com, Website: www.ready-access.