Installation Guide

Natural Gas Conversion Kit #00023109G
For use with Real Flame fireplaces: C9811LP
1
2
3
Natural Gas Hose and Quick Conversion Plaque
Connect (3/8” NPT)
NG Orifice Spud 3.9mm Cable Kit
Primary Air Mixer Sleeve
4
5
4
3
1
2
5
3
PARTS LIST
08-50KNG-V04
CSA MC# No. :251993
This appliance was converted on _________________
(DD/MM/YY)
to Natural Gas with Kit No._______________________
(Found on Box)
by___________________________________________,
par
Name and address of organization making this conversion)
Cet appareil a é converti le
en gaz naturel avec le kit no.
Type of Gas / Type de gaz: Natural Gas/Gaz Naturel
Normal Hourly Input/Entrée horaire normal:
50,000 BTU/Hr. (14.65 kW)
Manifold Pressure/Pression d'admission:
7.0” water column (1.74 kPa)
The minimum inlet pressure :
3.5” water column (0.87 kPa)
The maximum inlet pressure :
10.5” water column (2.61 kPa)
Après avoir transformé cette table à feu, cette plaque doit être
suspendue au centre du panneau de commande avec le câble fourni.
which accepts the responsibility that this conversion has
been properly made.
qui accepte la responsabilité que cette conversion a été faite correctement.
After converting this appliance, this plaque must be hung from the
center of the control panel with the provided cable.
This appliance has been converted to use Natural Gas.
Cette table a
été convertie en gaz naturel.
For technical support call: 1-800-654-1704
3.9