Installation manual
14
TROUBLE SHOOTING FOR ELECTRONIC IGNITION AND
POWER FLUE SYSTEM.
(continued)
The power flue and electronic control box have a red LED light that indicates the
possible cause of a problem, the LED light will flash in different sequences for
different problems, the most common are:-
Long Flash Short Flash
1 0 Normal Running State.
1 1 Flame Failure.
1 2 Waiting for pressure switch ON
1 3 Waiting for pressure switch OFF
2 1 Maximum retries exceeded