® MAGIGLO SERIES INSTALLATION & OPERATING MANUAL The Magiglo series of decorative fires are suitable to be installed into a masonry or approved prefabricated fireplace and are designed to operate with Natural and Propane gases only. Approval Number 6094.
WARRANTY Provided your Real Flame gas burner is installed in strict accordance with our installation instructions, the burner is unconditionally guaranteed for twelve months from date of purchase. This unconditional warranty covers parts and labour at our discretion taking into consideration normal wear and tear and does not cover fires installed in outdoor settings.
CONTENTS Contents ..................................................................................................................3 Data Plate.................................................................................................................4 Dimensions ..............................................................................................................4 Installation Instructions ............................................................................................
DATA PLATE (Affixed to the base of the unit for reference to gas pressure & consumption) Model 320 360 400 540 NG 750 NG LPG NG LPG NG LPG Injector 2.4 1.2 2.5 1.3 2.4 1.3 LPG MJ / HR 24 20 26 23 28 23 37 31 39 36 P.T.P. 0.8 2.7 0.8 2.7 0.8 2.7 0.8 2.6 0.64 2.55 2x2.2 2x1.1 NG LPG 2x2.5 2x1.2 DIMENSIONS Model 320 360 400 540 750 DBL A 165 165 165 150 150 150 B 320 360 400 540 750 540 C 120 120 210 210 210 280 All dimensions in mm.
INSTALLATION INSTRUCTIONS IMPORTANT This product is fitted with an OXYGEN DEPLETION SYSTEM which is an INTEGRAL PART OF THE PILOT. You must maintain the correct pressure for the oxygen depletion system to operate correctly (see data plate on page 4). When checking gas pressure at the appliance ALL OTHER GAS APPLIANCES IN PREMISES MUST BE OPERATING AT THE SAME TIME. Failure to have correct pressure may result in unit cutting out intermittently. TYPE OF INSTALLATIONS TYPE 1.
FOR YOUR SAFETY READ BEFORE LIGHTING The appliance has a pilot which must be lit using the piezo ignition, when lighting the pilot follow the instructions exactly. Before lighting the appliance check for gas leaks. Use only your hand to push in and turn the gas control knob, never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempt to repair may result in a fire or explosion.
COMMISSIONING PROCEDURE Once the fire is installed and operational the installer must check for spillage. Carry out the lighting procedure and turn the fire to high. Allow to warm up for 10 minutes and then using a smoke match set 25mm down and 25mm inside of the fire opening run the match across the width of the opening to check that all of the smoke is drawn away.
TYPICAL TYPE 1 INSTALLATION TO EXISTING CHIMNEY 225mm DIA GAS COWL TYPICAL TYPE 1 INSTALLATION TO EXISTING CHIMNEY OFF PI T LO Smoke match spillage test. Ensure gas log fire is set back into fire place in order that no waste products come into the room.
TYPE 1 INSTALLATION INTO VICTORIAN/FEDERATION GRATE EDWARDIAN/VICTORIAN GRATE AIR TUBES COALS CERAMIC BLANKET BURNER PORT CUT OUT SECTION CONTROL BASE GRATE FRONT IRON COAL PLACEMENT Place Air Tubes 5mm behind Burner Port and space evenly. (cut to size if too long). AIR TUBES 5mm GAP BURNER HOUSING BURNER PORT Place base layer of coals as above and randomly stack remainder allowing for gaps.
TYPICAL TYPE 2 INSTALLATION OF PREFABRICATED FIRE BOX INTO EXISTING CHIMNEY FOR INSTALLATION OF FIRE BOX REFER TO MANUFACTURER’S SPECIFICATIONS. SEAL FLANGE TO BRICKWORK OFF PI L 225mm DIA GAS COWL OT EXISTING CHIMNEY SEAL FLANGE TO BRICKWORK CONVECTION BOX MAGIGLO GAS SET ATTENTION ATTENTION: This is a guide only. Installation This is a guide only. Installation of Fire Box of Fire Box must bemust carried out be carried out to manufacturers specifications. to manufacturers specifications.
USER INSTRUCTIONS 1. Your Magiglo Gas Log/Coal Set will have been installed by an authorised person in accordance with the Installation and Service Instructions. If you are technically minded you will increase your knowledge of your fire by reading through these Instructions 2. Initially your Magiglo may burn with a slightly blue flame which part of the protective coating on the coal and logs burn off. A slight smell my also be apparent at this stage.
CONVERSION DETAILS PROPANE TO NATURAL GAS Parts Required Description PART No. 1 3/8˝ male x 1/2˝ male Hex Nipple 05 2 1/2˝ SC-75 Regulator 02 3 1/2˝ male x 1/2˝ Copper Union 04 4 Natural gas Oxy Pilot Assembly 03N 5 Natural gas Main Burner Injector (Refer to data plate for correct size) 010 Procedure 1. Remove connection fitting from control valve and replace with 3/8˝ male x 1/2˝ male hex nipple. 2. Fit regulator to hex nipple. 3. Fit 1/2˝ male x 1/2˝ copper union regulator. 4.
PARTS LIST PART No. DESCRIPTION PART No. 01 BM 733 Control Valve 05 1/2˝ to 3/8˝ Hex Nipple 02 Regulator SC-75 06 5/16˝ 90O Union Elbow S.I.T. ODS Pilot Assembly (Natural Gas) 07 1/4˝ Nut and Olive S.I.T.
REAL FLAME PTY LTD ABN 76 006 311 155 Head Office/Factory/Showroom 1340 Ferntree Gully Rd. Scoresby Vic 3179 Ph: (03) 8706 2000 Fax: (03) 8706 2001 E-mail: info@realflame.com.au Richmond - VIC Showroom 300 Swan St. Richmond Vic 3121 Ph: (03) 9428 4443 Fax: (03) 9428 4445 Geelong - VIC Showroom 1/2A Gordon Avenue. Geelong West Vic 3218 Ph/Fax: (03) 5229 0844 E-mail: realflamegeelong@hotmail.com.au Sydney - NSW Showroom 654 Pacific Highway.