The Real Fyre gas burner system is to be installed only
in a solid-fuel burning fireplace with a working flue and
constructed of noncombustible material. The installation,
including provisions for combustion and ventilation air
must conform with the National Fuel Gas Code, ANSI
Z223.1/NFPA 54, or the CSA B149.1, Natural Gas
and Propane Installation Code, and applicable local
building codes.
A damper clamp is included to maintain the minimum
permanent vent opening and to prevent full closure
of the damper blade. The chimney damper MUST
be fully opened when burning the unit. The unit is
designed to burn with yellow flames; thus adequate
ventilation is absolutely necessary.
To comply with certification, listings, and building
code acceptances, and for safe operation and proper
performance of this gas burner system, you must use
ONLY Peterson parts and accessories. Use of any other
controls, parts, or accessories not designed for use with
Real Fyre gas burner system is prohibited. This will void
all warranties, certifications, listings, and building code
approvals, and may cause property damage, personal
injury, or loss of life. Peterson will not be liable for any
damages caused by this misuse.
*Note: Solid-fuels shall not be burned in a fireplace
where a decorative appliance is installed.
FOR INSTALLATION IN
SOLID-FUEL BURNING
FIREPLACES*
IMPORTANT: READ THESE INSTRUCTIONS
CAREFULLY BEFORE STARTING
INSTALLATION OF THE UNIT.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
Open a window.
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in the building.
Immediately call the gas supplier
from a neighbor’s phone. Follow gas
supplier’s instructions.
If you cannot reach the gas supplier,
call the fire department.
WARNING
If the information in this manual is not
followed exactly, a fire or explosion
may result, causing property damage,
personal injury, or loss of life.
This appliance is only for use with the type
of gas indicated on the rating plate.
Installation and service must be performed by
a qualified professional service technician,
service agency, or the gas supplier.
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
INSTALLATION &
OWNER’S MANUAL
G45-GL VENTED GAS BURNER SYSTEMS (MANUALLY LIGHTED)
Burner Systems:
G45-GL-16/19(P)
G45-GL-18(P)
G45-GL-24(P)
G45-GL-30(P)
G45-GL-36(P)
G45-GL-42(P)
G45-GL-48(P)
G45-GL-60(P)
For use w/ propane or natural gas
Design Certified
to:
Z21.84b
(16/19" - 30" models)

Summary of content (18 pages)