Spec Sheet 2

1
L-A2-227
REV 8 - 1705081545
ROBERT H. PETERSON CO. • 14724 East Proctor Avenue • City of Industry, CA 91746
OWNER’S
OWNER’S
MANUAL
MANUAL
Standard Burner Systems:
PB-**(P)A
PB-**-01(M)(P)
PB-**-11(M)(P)
PB-**-15(M)(P)
PB-**-17(M)(P)
**Sizes:
(18, 24, 30)
The Real-Fyre gas burner system is to be installed only
in a solid-fuel burning fi replace with a working fl ue and
constructed of noncombustible material. The installation,
including provisions for combustion and ventilation air
must conform with the National Fuel Gas Code, ANSI
Z223.1/NFPA 54, or the CSA B149.1, Natural Gas
and Propane Installation Code, and applicable local
building codes.
A damper clamp is included to maintain the minimum
permanent vent opening and to prevent full closure of
the damper blade. The chimney damper MUST be fully
opened when burning the burner system. The burner
system is designed to burn with yellow fl ames;
thus adequate ventilation is absolutely necessary.
To comply with certification, listings, and building
code acceptances, and for safe operation and proper
performance of this burner system, use ONLY Peterson
parts and accessories. Use of other controls, parts, and
accessories that are not designed for use with Real-
Fyre gas burner systems is prohibited and will void all
warranties, certifi cations, listings, and building code
approvals, and may cause property damage, personal
injury, or loss of life.
*Note: Solid-fuels shall not be burned in a fi replace
where a decorative appliance is installed.
IMPORTANT: READ THESE INSTRUCTIONS
CAREFULLY BEFORE STARTING
INSTALLATION OF THE SYSTEM
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
Open a window.
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in the building.
Immediately call the gas supplier
from a neighbor’s phone. Follow gas
supplier’s instructions.
If you cannot reach the gas supplier,
call the fi re department.
WARNING
If the information in this manual is not
followed exactly, a fire or explosion
may result, causing property damage,
personal injury, or loss of life.
This appliance is only for use with the
type of gas indicated on the rating plate.
Installation and service must
be performed by a qualified
professional installer, service
agency, or the gas supplier.
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
PB SERIES VENTED GAS BURNER SYSTEMS (REGULATED)
FOR INSTALLATION IN
SOLID-FUEL BURNING
FIREPLACES*
DESIGN CERTIFIED
to
Vented Decorative Appliance
ANSI Z21.60-2012
CSA 2.26-2012
FOR USE WITH
FYRE GLASS / FYRE GEMS
16-212
US
®
C