Datasheet

www.recom-international.com PA-3REV: 0/2014
POWERLINE
AC/DC-Converter
Standard Package Style and Pinning
Pin Connections
Pin # Single Output
1 VAC in (N)
2 VAC in (L)
3 -VDC out
4 +VDC out
1
Bottom View
Top View
3
4
2
Allow 5mm clearance around converter for air circulation
15.24
22.2
2.54
1.0
ø
+0.2/0.1
0.6
ø
33.7
17.0
6.1
2.54
17.75
±0.25
0.75±0.25
7.62
7.62
7.62
5.0
28.0
2.54
Leave Clear
of
PCB Traces
Tolerance ± 0.5 mm
unless otherwise specified
Recommended Application Circuit
Compact single output regulated power supply
Suggested fuse rating: 1A Slow Blow.
An external MOV is required for 230VAC opera-
tion. The varistor should comply with IEC-61051-
2 e.g. Epcos S14 series
Package Weight 25g
Packing Quantity 22 pcs
EMC Conducted and Radiate EN55022 Class B
Noise Immunity EN55024
MTBF +25°C 666 x 10
3
hours
230VAC +55°C 395 x 10
3
hours
using MIL-HDBK-217F +80°C 125 x 10
3
hours
Certifications:
UL General Safety File Nr. E224736 UL-60950-1, 2nd Edition
EN General Safety SPCLVD 1202026 EN-60950-1, 2nd Edition
CE Report: 2011-04-19 EN55022 Class B
Specifications
(Ta=25°C and after warm up time, measured at 115VAC/60Hz and 230VAC/50Hz )
N
Load
C1(Optional)
330uF
L
1A Fuse
MOV
- required for
230VAC Surge
Protection only
Add C1 to reduce output ripple (use low ESR type)
VACin (L)
VACin (N)
Vout+
Vout-
RAC02-05SC
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
230VAC
115VAC
RAC01-05SC
RAC01-SC
RAC02-SC
Input Voltage Derating Graph
Load (%)
Input Voltage (VAC) Ta=25°C
Safe Operating Area
100%
90%
80%
70%
80
130 180
230
280
90V, 100%
85V, 90%
80V, 80%
RAC01-02
Notes:
Note1: Measured @ 230VAC / 50Hz / Ta=25°C with constant resistant mode at full load.
Note2: If used @ 115VAC / 60Hz with full load, max. capacitive load is less, please contact RECOM for detailed information.
The product information and specifications are subject to change without prior notice. All products are designed for non-safety critical commercial and industrial applications.
The Buyer agrees to implement safeguards that anticipate the consequences of any failures that might cause harm, loss of life and/or damage property.