Datasheet
www.recom-power.com
REV.: 4/2018 I-7
DC/DC Converter
Specifications (refer to standard application circuit, Ta= 25°C)
R-6xxxP_D
Series
Positive to Negative Converter
Pin Connections
Pin # Negative Out Positive Out
1 ON/OFF ON/OFF
2,3,4 +Vin +Viin
5, 6, 7, 8 -Vout GND
9, 10, 11 GND +Vout
12 -Vadj +Vadj
PACKAGING INFORMATION
Parameter Type Value
Packaging Dimensions (LxWxH)
R-6xxxD
R-6xxxP
520.0 x 20.0 x 19.0mm
530.0 x 23.0 x 19.0mm
Packaging Quantity tube 15pcs
Storage Temperature Range -40°C to +125°C
Bottom View
Top View
1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
2.54
2.54
9.1
32.2
11 x 2.54 = 27.94
0.8
0.70
+0.10/-0.05
0.25
±0.05
15.04.10
Marking
embossed logo
2.1
Ref. to -Vout
C1 and C2 are required
and should be fitted close
to the converter pins.
C1
C2
+V
in
-V
out
V
adj
GND
ON/OFF
+V
in
-V
out
GNDGND
ON/OFF
R
1
R
2
R-6xxxP_D
The
product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer.
The
products
are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or
cause
loss
of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the
unauthorized
use of RECOM products in such safety-critical applications.
Part Input Output Vout Output Efficiency Max. Capacitive
Number Voltage Range Voltage Adjust Range
(1)
Current @ min Vin @ max. Vin Load
(7)
[VDC] [VDC] [VDC] [A] [%] [%] C1 C2
R-621.8 9 - 28 -1.8 -1.5~ -3.6 -1 72 65 10µF/50V 100µF/6.3V
R-622.5 9 - 28 -2.5 -1.5~ -4.5 -1 76 72 10µF/50V 100µF/6.3V
R-623.3 9 - 28 -3.3 -1.8~ -6 -1 79 76 10µF/50V 100µF/10V
R-625.0 9 - 28 -5 -1.8~ -9 -1 81 80 10µF/50V 100µF/10V
R-629.0 11 - 26 -9 -3.3~ -15 -0.8 84 85 10µF/50V 100µF/25V
R-6212 11 - 26 -12 -3.3~ -15 -0.6 86 88 10µF/50V 100µF/25V
Selection Guide (Positive to Negativ)
Notes:
Note7: Maximum capacitive load including C2 is 220µF