Datasheet

INNOLINE
DC/DC-Converter
with 3 year Warranty
R-6xxx
www.recom-international.comI-44 REV: 1/2013
EN-60950-1 Certified
1-2 AMP
SIP12
Vertical
&
Horizontal
Adjustable Output Voltage
Non-Isolated
1-2AMP Adjustable Positive Step Down
Integrated Switching Regulator
Internal Short Circuit Protection
ON/OFF Control(Ground Off)
UL94V-0 Package Material
Wide Input Range
Efficiency to 96%
See Innoline Application Notes for use as an
inverter
Features
Selection Guide
Specifications (refer to the standard application circuit, Ta: 25°C)
Characteristics Conditions Min. Typ. Max.
Input Voltage Range Vout = 1.8V 9V 32V
Vout = 2.5V 9V 32V
Vout = 3.3V 9V 32V
Vout = 5V 9V 32V
Vout = 9V 11V 32V
Vout = 12V 14V 32V
Vout = 18V 20V 32V
Output Voltage Adjust Range (see table 1) Vout = 1.8V 1.5V 1.8V 3.6V
Vout = 2.5V 1.5V 2.5V 4.5V
Vout = 3.3V 1.8V 3.3V 6V
Vout = 5V 1.8V 5V 9V
Vout = 9V 3.3V 9V 15V
Vout = 12V 3.3V 12V 15V
Vout = 18V 18V
Continued on next page
Part Input Nominal Vout Output Efficiency (%)
Number Range Output Voltage Adjust Range Current Vin min. Vin max.
SIP12 (V) (V) (V) (A) (%) (%)
R-611.8x 9 – 32 1.8 1.5 – 3.6 1 79 67
R-612.5x 9 – 32 2.5 1.5 – 4.5 1 84 74
R-613.3x 9 – 32 3.3 1.8 – 6 1 88 79
R-615.0x 9 – 32 5 1.8 – 9 1 92 84
R-619.0x 11 – 32 9 3.3 – 15 1 96 90
R-6112x 14 – 32 12 3.3 – 15 1 97 92
R-621.8x 9 – 32 1.8 1.5 – 3.6 2 76 68
R-622.5x 9 – 32 2.5 1.5 – 4.5 2 81 74
R-623.3x 9 – 32 3.3 1.8 – 6 2 86 80
R-625.0x 9 – 32 5 1.8 – 9 2 90 85
R-629.0x 11 – 32 9 3.3 – 15 2 95 91
R-6212x 14 – 32 12 3.3 – 15 2 96 93
Note: Vin -Vout 1.5V if adjust function is used!
Suffix x: (see mechanical drawing for details)
x = P pins vertical through hole
x = D pins bent for horizontal through hole mounting
The R-6XXX series is a high performance 1.5V to 15V (18V), 1.1Amp to 2.0Amp,12-Pin
SIP (single in-line package) switching regulator. Synchronuous rectification yields excellent
efficiencies of up to 97%. The devices feature short circuit protection with internal crowbar
function to reduce the short circuit input current to under 50mA during fault conditions.
Description
RoHS
2011/65/EU
6/6