Datasheet

www.recom-power.com
REV.: 5/2018 I-7
DC/DC Converter
Specifications (refer to standard application circuit, Ta= 25°C)
R-7xxxP_D
Series
INSTALLATION AND APPLICATION
C1
C2
Q1
1µF
(Optional)
100µF
ESR= 150m max.
(Required)
+V
in
+V
out
V
adj
GND
ON/OFF
+V
in
Com Com
+V
out
R
down
R
up
R-7xxxP_D
OFF
ON
V
CTRL
Standard Application Circuit
Add blocking diode to Vout if current can flow backwards into the output, as this can damage the converter.
(Please refer to “Optional Diode Protection Circuit” on Page I-5)
PACKAGING INFORMATION
Parameter Type Value
Packaging Dimensions (LxWxH)
R-7xxxD
R-7xxxP
520.0 x 20.0 x 19.0mm
530.0 x 23.0 x 19.0mm
Packaging Quantity tube 15pcs
Storage Temperature Range -40°C to +125°C
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized