Datasheet
R-xxB
Typical Applications
Rxx-100_150B
Series
INNOLINE
DC/DC-Converter
+Vin
Load
Rxx-
100_150B
C2
4700 pF,
250VDC
VR = 5 k
W
9,16
-Vin
8,17
Vout
Com
C1
47µF
Vref
Vadj
R2 R1
22,23
2,3
12,13
10,15
Resistance Control
Output Voltage
Max
Min
R2 5kW
R1 0W
0W
5kW
(1)
(2)
For remote voltage control
+Vin
Load
Rxx-
100_150B
C2
4700 pF,
250VDC
+ -
-Vin
8,17
Vout
Com
C1
47µF
Vadj
22,23
2,3
12,13
10,15
Link -Vin and Com for
GND-referenced
remote voltage control
(Output is no longer isolated)
Voltage Control
Output Voltage
Max
Min
1V
2V
3V
4V
+Vin
Load
Rxx-
100_150B
C3
4700 pF,
250VDC
R = 5 k
W
9,16
-Vin
8,17
Vout
Com
C1
47µF
Vref
Vadj
22,23
2,3
12,13
10,15
Rxx-
100_150B
C4
4700 pF,
250VDC
VR = 5 k
W
9,16
8,17
Vout
Com
C2
47µF
Vref
Vadj
R2 R1
22,23
2,3
12,13
10,15
Cascade Combinations
U1 U2 Vout Range
R05-100B R05-100B 160-240
Rxx-100B Rxx-100B 190~270
Rxx-150B Rxx-100B 230~345
Rxx-150B Rxx-150B 305~420
xx = 12, 15 or 24
Note: When cascaded, only one Rxx-B
may be adjustable, the other must be
fixed voltage.
www.recom-power.com I-61REV: 2/2016
Note1: 0Ω means Vadj connected to COM; no connection to Vref
Note2: 0Ω means Vadj connected to Vref; no connection to COM