Description
The RxxPxxS_D Series of DC/DC Converters are certified to UL/CSA60950-1. This makes them ideal for
safety applications where approved or reinforced isolation is required. The reinforced versions are also
EN61010-1 certified for Lab Equipment Safety.
DC/DC Converter
1 Watt
SIP7
Single and Dual
Output
E314885
EN/IEC60950-1 certified
EN/IEC60601-1 certified
UL/CSA 60950-1 certified
ES/CSA60601-1 certified
EN/IEC61010-1 certified
IEC-60601-1 CB report
www.recom-power.com/eval-ref-boards www.recom-power.com/bier
RxxPxx/R
Features
Unregulated
Converters
Qualified with 65kV/µs @ Vcommon mode =1KV
EN61010 for test, measurement and lab use
EN60601 for medical applications
Reinforced isolation 6.4kVDC or 8kVDC
Optional continuous short circuit protection
Unique reinforced isolation transformer system
/X2 option for >9mm input/output clearance
Selection Guide
Part nom. Input Output Output Efficiency max. Capacitive
Number Voltage Voltage Current typ.
(1)
Load
(2)
[VDC] [VDC] [mA] [%] [µF]
RxxP3.3S/R
(3,4,5)
5, 12, 15, 24 3.3 303 70 - 80 2200
RxxP05S/R
(3,4,5)
5, 12, 15, 24 5 200 75 - 80 1000
RxxP09S/R
(3,4,5)
5, 12, 15, 24 9 111 75 - 82 1000
RxxP12S/R
(3,4,5)
5, 12, 15, 24 12 84 75 - 82 470
RxxP15S/R
(3,4,5)
5, 12, 15, 24 15 66 75 - 83 470
RxxP3.3D/R
(3,4,5)
5, 12, 15, 24 ±3.3 ±151 72 - 79 ±1000
RxxP05D/R
(3,4,5)
5, 12, 15, 24 ±5 ±100 75 - 82 ±470
RxxP09D/R
(3,4,5)
5, 12, 15, 24 ±9 ±55 75 - 82 ±470
RxxP12D/R
(3,4,5)
5, 12, 15, 24 ±12 ±41 75 - 82 ±220
RxxP15D/R
(3,4,5)
5, 12, 15, 24 ±15 ±33 75 - 83 ±220
Notes:
Note3: add suffix „/R6.4“ for 6.4kVDC/1second isolation or „/R8“ for 8kVDC/1second isolation
Note4: add suffix „/X2“ for single output with alternative pinout
Note5: add suffix „/P“ for continous short circuit protection
Model Numbering
Ordering Examples:
R05P3.3S/R8/P = 5V Input, 3.3V Output, Single Output, 8kVDC/1s isolation, Continous Short Circuit Protection
R24P05S/R6.4/P/X2 = 24V Input, 5V Output, Single Output, 6.4kVDC/1s isolation, Continous SCP, Alternative Pinout
R12P05D/R8/X2 = ±12V Input, ±5V Output, Dual Output, 8kVDC/1s isolation, Alternative Pinout
Reinforced Isolation
(3)
Pinout
(4)
Protection
(5)
Input Voltage
Output Voltage
Single or Dual
R__P__ _/P/X2/R
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Max. Capacitive Load is defined as the capacitive load that will allow start up
in under 1 second without damage to the converter