Datasheet

www.recom-power.com
REV.: 5/2018 ECO-2
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RxxPxx/R
Series
REGULATIONS
Parameter Condition Value
Output Accuracy ±5.0% max.
Line Regulation low line to high line, full load 1.2%/1% of Vin typ.
Load Regulation 10% to 100% load
3.3V, 5V
9V, 12V, 15V
15% typ.
10% typ.
continued on next page
BASIC CHARACTERISTICS
Parameter Condition Min. Typ. Max.
Input Voltage Range ±10%
Minimum Load
(5)
0%
Internal Operating Frequency
20kHz 50kHz 85kHz
Output Ripple and Noise
20MHz BW 200mVp-p
Notes:
Note5: Operation below 10% load will not harm the converter, but specifications may not be met
Efficiency vs. Load
0 10 20 30 40 50 60 70 80 90 100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
R05P05D
R12P05D
R24P05D
0 10 20 30 40 50 60 70 80 90
100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
R05P05S
R12P05S
R24P05S
PxxP05S/R6.4 and PxxP05S/R8 PxxP05D/R6.4 and PxxP05D/R8
Tolerance Envelope
10
-5%
-1.5%
+5%
+10%
Typical Load Line
+5%
Vnom
50 100
Output Voltage [%]
Load [%]