Datasheet

www.recom-power.com
REV.: 5/2018 ECO-3
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RxxPxx/R
Series
Deviation vs. Load
25
15
5
-5
20
10
0
-10
-15
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
R05P05S/R6.4
R12P05S/R6.4
R24P05S/R6.4
25
15
5
-5
20
10
0
-10
-15
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
R05P05D/R6.4
R12P05D/R6.4
R24P05D/R6.4
PROTECTIONS
Parameter Type Value
Short Circuit Protection (SCP)
without Suffix “/P”
with Suffix “/P”
1 second
continuous
Isolation Voltage
(8)
I/P to O/P
tested for 1 second
/R6.4
/R8
6.4kVDC
8kVDC
rated for 1 minute
/R6.4
/R8
3.2kVAC/60Hz
4kVAC/60Hz
Isolation Resistance 15G min.
Isolation Capacitance 4.0pF min. / 10pF max.
Leakage Current <0.01µA max.
Insulation Grade reinforced
Means of Protection
34Vrms
2MOPP
Internal
clearance/creepage >4.8mm
External
clearance/creepage >4.8mm
Notes:
Note7: For repeat Hi-Pot testing, reduce the time and/or the test voltage
ENVIRONMENTAL
Parameter Condition
Value
Operating Temperature Range without derating @ free air convection (see graph) -40°C to +85°C
Maximum Case Temperature +105°C
Operating Altitude 3000m
Operating Humidity non-condensing 95% RH max.
Pollution Degree PD2
MTBF according to MIL-HDBK-217F, G.B.
+25°C
+85°C
2974 x 10
3
hours
728 x 10
3
hours
continued on next page