Datasheet
www.recom-power.com
REV.: 5/2018 ECO-4
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RxxPxx/R
Series
-40 -20 0 20 40 7060-30 -10 10 30 50 80 90
85
110100
100
80
60
40
90
70
50
30
20
10
0
Output Load [%]
Ambient Temperature [°C]
Derating Graph
(@ Chamber and free air convection)
SAFETY AND CERTIFICATIONS
Certificate Type (Safety) Report / File Number Standard
Information Technology Equipment, General Requirements for Safety
1605077-14
EN60950-1: 2006 + AM2:2013
IEC60950-1-2005 , 2nd Edition + AM2:2013
Information Technology Equipment, General Requirements for Safety 2207629
ANSI/UL60950-1, 1st Edition
CAN/CSA C22.2 No. 60950-1
Medical Electric Equipment, General Requirements for Safety and
Essential Performance
2207629
UL60601-1, 1st Edition
CAN/CSA C22.2 No. 60.1-M90
Medical Electric Equipment, General Requirements for Safety and
Essential Performance
E314885-A5-UL
ANSI/AAMI ES60601-1:2005 +A2:10
CAN/CSA-C22.2 No. 60601-1:2008
Medical Electric Equipment, General Requirements for Safety and
Essential Performance. (CB Scheme)
E314885-A5-CB-1 IEC60601-1:2005 + C2:2007
Medical Electric Equipment, General Requirements for Safety and
Essential Performance
1205098-1
EN60601-1:2006
IEC60601-1:2005 + C2:2007
Safety requirements for electrical equipement for measurement, control
and laboratory use
T1301251-313
EN61010-1:2010
IEC61010-1:2010, 3rd Edition
EAC RU-AT.37.02367 TP TC 004/2011
RoHs 2+ RoHS (10/10)
EMC Compliance Condition Standard / Criterion
Electromagnetic compatibility of multimedia equipment -
Emission requirements
with external filter EN55032, Class A/B
continued on next page