Datasheet

E-54
www.recom-electronic.com
REV: 0/2011
RxxP2xx(/R)
Refer to Application Notes
ECONOLINE
DC/DC-Converter
with 3 year Warranty
RxxP2xx(R)
Selection Guide
Part Standard Reinforced Input Output Output Efficiency Max
Number Isolation Isolation Voltage Voltage Current Std (/R) Capacitive
SIP 7 (kVDC) (kVDC) (VDC) (VDC) (mA) (%) Load
(1)
RxxP23.3S 5.2 /R6.4 & /R8 5, 12, 15, 24 3.3 600 70 (72-78) 3300µF
RxxP205S 5.2 /R6.4 & /R8 5, 12, 15, 24 5 400 70-75 (79-84) 1200µF
RxxP209S 5.2 /R6.4 & /R8 5, 12, 15, 24 9 222 70-75 (80-87) 1200µF
RxxP212S 5.2 /R6.4 & /R8 5, 12, 15, 24 12 167 70-75 (80-87) 680µF
RxxP215S 5.2 /R6.4 & /R8 5, 12, 15, 24 15 132 75-80 (80-88) 680µF
RxxP23.3D 5.2 /R6.4 & /R8 5, 12, 15, 24 ±3.3 ±300 70 (73-80) ±1500µF
RxxP205D 5.2 /R6.4 & /R8 5, 12, 15, 24 ±5 ±200 70-75 (79-85) ±470µF
RxxP209D 5.2 /R6.4 & /R8 5, 12, 15, 24 ±9 ±111 70-75 (80-87) ±470µF
RxxP212D 5.2 /R6.4 & /R8 5, 12, 15, 24 ±12 ±85 70-75 (80-87) ±330µF
RxxP215D 5.2 /R6.4 & /R8 5, 12, 15, 24 ±15 ±66 75-80 (80-88) ±330µF
xx = Input Voltage. Other input and output voltage combinations available on request.
No suffux is functional isolation e.g,
R05P205S
* add Suffix “P” for Continuous Short Circuit Protection, e.g. R05P205S/P, R05P205D/P
* add Suffix “/X2” for single output with alternative pinout, e.g. R05P205S/X2, R05P205S/P/X2
* add Suffix “/R6.4” or “/R8” for Reinforced Isolation, e.g. R05P205D/R6.4, R05P205S/P/X2/R8
Output Power (%)
100
60
20
40
100500-40
85
150
Operating Temperature °C
0
80
Safe Operating Area
Input Voltage Range ±10%
Output Voltage Accuracy ±5%
Line Voltage Regulation 1.2%/1% of Vin typ.
Load Voltage Regulation 3.3, 5V output types 15% max.
(10% to 100% full load) other output types 10% max.
Output Ripple and Noise (20MHz BW) 200mVp-p max.
Operating Frequency 20kHz min. / 50kHz typ. / 85kHz max.
Efficiency at Full Load 65% min. / 80% max.
Minimum Load = 0% Specifications valid for 10% minimum load only.
Isolation Voltage (tested for 1 second) 6400VDC
(rated for 1 minute) 3200VAC / 60Hz
/R6.4 (tested for 1 second) 6400VDC
(rated for 1 minute) 3200VAC / 60Hz
/R8 (tested for 1 second) 8000VDC
(rated for 1 minute) 4000VAC / 60Hz
Isolation Capacitance 1.5pF min. / 10pF max.
Isolation Resistance 15 GΩ min.
Short Circuit Protection 1 Second
P-Suffix Continuous
Operating Temperature Range (free air convection) -40°C to +85°C (see Graph)
Storage Temperature Range -55°C to +125°C
Relative Humidity 95% RH
cont.
2 Watt
SIP 7 Single &
Dual Output
Derating-Graph
(Ambient Temperature)
UL/CSA and EN Safety certified
EN-61010 for Test, Measurement and Lab. Use
EN-60601 for Medical Applications
Standard Isolation 5.2kVDC
Optional Reinforced Isolation 6.4kVDC or 8kVDC
Optional Continuous Short Circuit Protected
Unique Transformer System (Patent Pending)
Compact SIP7 Package
Efficiency to 88%
Features
Unregulated
Converters
Description
Specifications (measured at T
A
= 25°C, nominal input voltage, full load and after warm-up)
The RxxP2xxS_D Series of DC/DC Converters are
fcertified to UL/CSA-60950 and UL/CSA 60601. This
makes them ideal for medical and safety applications
where approved or reinforced isolation is required.
The reinforced versions are also EN61010-1 certified
for Lab Equipment. The /X2 version has an input/
output clearance of more than 9mm.
EN-60950-1 Certified
EN-60601-1 Certified
UL/CSA 60950-1 Certified
UL/CSA 60601-1 Certified (/R)
EN-61010-1 Certified (/R)
E-224736
RoHS
2002/95/EC
6/6