Datasheet
I-60 www.recom-power.comREV: 2/2016
Specifications ( typical at 25°C, nominal input voltage, full load unless otherwise specified )
INNOLINE
DC/DC-Converter
with 3 year Warranty
Rxx-B
IEC/EN60950-1 Certified
RoHS
2011/65/EU
6/6
5 Watt
Single
Output
● High Output Voltage DIP24 converter
● Improved Version of Rxx-100_150A Series
with higher efficiency and reduced ripple.
● Input Voltage 5, 12, 15 or 24VDC
● Adjustable Output Voltage up to 200VDC
● Cascadable for Output Voltages up to 420VDC
● 3kVDC Input/Output Isolation
● Remote Voltage Programming by External
Voltage or Resistance
● Continuous Short Circuit Protection
● Ambient Temperature up to +85°C
Features
Regulated
Converters
Selection Guide
Input Voltage Range 5, 12, 15 or 24VDC
Rated Power 5V 25mA max. or 3 Watts max.
All others 50mA max. or 5 Watts max.
Output Voltage Adjustment Range 41..135 or 92..200VDC
Output Voltage Accuracy ±5% max
Line Voltage Regulation 0.5% max
Load Voltage Regulation 20% to 100% full load 0.5% max
Output Ripple and Noise 20MHz limited 60mVp-p typ. / 100mVp-p max.
Operating Frequency 200kHz typ.
Isolation Voltage (tested for 1 second) 3000VDC min.
Isolation Capacitance 20pF typ.
Isolation Resistance 1 GΩ min.
Short Circuit Protection Continuous, Automatic Restart
Short Circuit Input Current 30mA typ.
Temperature Coefficient ±0.02%/°C
Operating Temperature Range With derating -40°C to +85°C
(free air convection) Full Power -40°C to +70°C
Storage Temperature Range -50°C to +125°C
Case Material Non-Conductive Black Plastic
Potting Material Epoxy (UL94V-0)
Weight 12g
MTBF (25°C) Mil-Std 217F 1400 x 10³ hours
Output Voltage Adjust External Voltage 0 - 4VDC
External Resistor 0 - 5kΩ
Internal Voltage Reference Regulated 5V with 1kΩ series resistor
IEC/EN General Safety Report: SPCLVD 1605077-02 EN60950-1, 2nd Edition + A2:2013
Derating-Graph
(Ambient Temperature)
125
75
50
25
0
100
Ambient Temperature Range (°C)
-40 -10 0 50 60
70
80 90 100
Output Power (%)
Natural Convection
60
85
Part Input nominal Output Output Max Output Efficiency
Number Range Voltage Voltage Range Current at Full Load
DIP 24 (VDC) (VDC) (VDC) (mA) (%)
R05-100B 5 ( 4.5 – 6 ) 87 +41...+120 25 77
R12-100B 12 ( 10 – 14 ) 103 +50...+135 50 82
R15-100B 15 ( 14 – 17 ) 103 +59...+130 50 82
R24-100B 24 ( 21 – 27 ) 105 +56...+135 50 84
R12-150B 12 ( 10 – 14 ) 159 +92...+200 50 82
R15-150B 15 ( 14 – 17 ) 159 +92...+200 50 82
R24-150B 24 ( 21 – 27 ) 159 +92...+200 50 84