Datasheet
www.recom-power.com
REV.: 6/2018 ECO-2
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RxxP2xx
Series
REGULATIONS
Parameter Condition Value
Output Accuracy ±5.0% max.
Line Regulation low line to high line, full load 1.2%/1% of Vin typ.
Load Regulation 10% to 100% load
3.3, 5VDC
9, 12, 15VDC
15% typ.
10% typ.
continued on next page
BASIC CHARACTERISTICS
Parameter Condition Min. Typ. Max.
Input Voltage Range ±10%
Minimum Load
(5)
0%
Internal Operating Frequency
20kHz 50kHz 85kHz
Output Ripple and Noise
(6)
20MHz BW 200mVp-p
Notes:
Note5: Operation below 10% load will not harm the converter, but specifications may not be met
Note6: Measurements are made with a 0.1µF MLCC across output (low ESR)
Efficiency vs. Load
PxxP205S and PxxP209S
PxxP212S and PxxP215S
PxxP205D and PxxP209D
PxxP212D and PxxP215D
0 10 20 30 40 50 60 70 80 90 100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
R05P205D
and R12P205D
R05P209D
R12P209D
0 10 20 30 40 50 60 70 80 90 100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
R05P212D
R12P212D
R05P215D
R12P215D
0 10 20 30 40 50 60 70 80 90
100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
R05P205S
and R12P205S
R05P209S
R12P209S
0 10 20 30 40 50 60 70 80 90
100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
R05P212S
R12P212S
R05P215S
R12P215S