Datasheet

www.recom-power.com
REV.: 6/2018 ECO-4
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RxxP2xx
Series
ENVIRONMENTAL
Parameter
Condition
Value
Operating Temperature Range without derating @ free air convection (see graph) -40°C to +90°C
Operating Altitude 2000m
Operating Humidity non-condensing 95% RH max.
Pollution Degree PD2
MTBF according to MIL-HDBK-217F, G.B.
+25°C
Single
Dual
2113 x 10
3
hours
2434 x 10
3
hours
+85°C
Single
Dual
299 x 10
3
hours
334 x 10
3
hours
-40 -20 0 20 40 7060-30 -10 10 30 50 80 90
95
110100
100
80
60
40
90
70
50
30
20
10
0
Output Load [%]
Ambient Temperature [°C]
Derating Graph
(@ Chamber and free air convection)
PROTECTIONS
Parameter Type Value
Short Circuit Protection (SCP)
without Suffix “/P”
with Suffix “/P”
1 second
continuous
Isolation Voltage
(7)
I/P to O/P
tested for 1 second 6.4kVDC
rated for 1 minute 3.2VAC/60Hz
Isolation Resistance 15GΩ min.
Isolation Capacitance 1.5pF min. / 10pF max.
Insulation Grade basic
Notes:
Note7: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note8: Refer to local wiring regulations if input over-current protection is also required. Recommended fuse: T1A slow blow type