Data Sheet

www.recom-power.com
REV.: 8/2019 I-4
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin and full load)
Rxx-100_150B
Series
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report / File Number
Standard
Information Technology Equipment, General Requirements for Safety
SPCLVD1605077-02
IEC60950-1:2005, 2nd Edition + AM 2:2013
EN60950-1:2006 + AM 2:2013
EAC RU-AT.49.09571 TP TC 004/2011
RoHS2+ RoHS-2001/65/EU + AM-2015/863
ENVIRONMENTAL
Parameter Condition
Value
Operating Temperature Range
with derating @ free air convection (see graph)
full load @ free air convection (see graph)
-40°C to +85°C
-40°C to +70°C
Temperature Coefficient ± 0.02%/K
Operating Altitude 2000m
Operating Humidity non-condensing 95% RH max.
Pollution Degree PD2
MTBF according to MIL-HDBK-217F, G.B. +25°C 1400 x 10
3
hours
-40 -20 0 20 40 70
85
60-30 -10 10 30 50 80 90 100
100
80
60
40
90
70
50
30
20
10
0
Output Load [%]
Ambient Temperature [°C]
Derating Graph
(@ free air convection)
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter Type Value
Material
case
potting
PCB
non conductive black plastic, (UL94 V-0)
epoxy, (UL94 V-0)
FR4, (UL94 V-0)
Package Dimension (LxWxH) 31.2 x 20.3 x 9.4mm
Package Weight 12g typ.
continued on next page