DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin and full load)
Rxx-100_150B
Series
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer.
The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or
cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the
unauthorized
use of RECOM products in such safety-critical applications.
PACKAGING INFORMATION
Parameter Type Value
Packaging Dimension (LxWxH) tube 530.0 x 23.0 x 19.0mm
Packaging Quantity tube 6pcs
Storage Temperature Range - 50°C to +125°C
Storage Humidity 95% RH max.
47µF
C1
C1
4700pF, 250VDC
C2
+V
IN
-V
IN
+V
OUT
-V
OUT
Rxx-100_150B
22,23
2,3
Vadj
+ -
Link -Vin and Com for
GND-referenced
remote voltage control
(Output is no longer isolated)
8,17
10,15
12,13
Com
Vout
47µF
C1
C1
4700pF, 250VDC
C3
+V
IN
-V
IN
V
OUT
Rxx-100_150B
22,23
2,3
9,16
Vref Vadj
R2 R1
VR = 5kΩ
8,17
10,15
12,13
Com
47µF
C2
C1
4700pF, 250VDC
C4
V
OUT
Rxx-100_150B
22,23
2,3
9,16
Vref Vadj
R2 R1
VR = 5kΩ
8,17
10,15
12,13
Com
For Remote Voltage Control
Cascade Circuit
Cascade Combinations
U1 U2 Vout Range
R05-100B R05-100B 160-240
Rxx-100B Rxx-100B 190~260
Rxx-150B Rxx-100B 230~330
Rxx-150B Rxx-150B 305~400
xx = 12, 15 or 24
Note: When cascaded, only one Rxx-B may
be adjustable, the other must be fixed voltage.
Min
1 2 3 4
Voltage Control [VDC]
Output Voltage
Max