Datasheet

RxxP2xx
Typical Characteristics
ECONOLINE
DC/DC-Converter
Operating Temperature Range (free air convection, without derating) -40°C to +90°C (see Graph)
Storage Temperature Range -55°C to +125°C
Relative Humidity 95% RH
Package Weight 4.3g
Packing Quantity 25 pcs per Tube
MTBF (+25°C) Single/Dual using MIL-HDBK 217F 2113/2434 x 10
3
hours
. (+85°C) Single/Dual using MIL-HDBK 217F 299/334 x 10
3
hours
Certifications
UL/cUL General Safety Report: E358085-A8 UL 60950-1 2nd Ed.
EN General Safety Report: SPCLVD1305069 EN60950-1:2006 + A12: 2011
EN Medical Safety Report: SPCMDD1205098-4 IEC/EN60601-1:2006, 3rd Edition
Specifications (measured at T
A
= 25°C, nominal input voltage, full load and after warm-up)
Tolerance Envelope
+10%
+5%
V Nom.
+5%
 1.5%
10% 50% 100%
Output Voltage
Output Load Current (%)
 5%
Typical Load Line
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
R05P209S
R12P09S
R05P205S,
R12P205S
RxxP209S
R05P209D
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
R05P209D
R12P209D
R05P205D,
R12P205D
Deviation / Load
-10.000
40%0% 100%
Deviation from Nominal (%)
60%
80%
20%
-5.000
Total Output current (%)
R05P205D
0.000
5.000
10.000
15.000
20.000
25.000
R12P209D
R05P209D
R12P205D
Deviation / Load
-10.000
40%0% 100%
Deviation from Nominal (%)
60%
80%
20%
-5.000
Total Output current (%)
0.000
5.000
10.000
15.000
20.000
25.000
R12P209S
R05P205S
R05P209S
R12P205S
}
Detailed Information see
Application Notes chapter "MTBF"
Notes
Note 1 Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter.
RxxP2xxS_D
Series
RxxP205S
R05P205D
REV: 2/2015 E-97www.recom-power.com