Datasheet

R2S-R2D
R2S & R2D
Series
ECONOLINE
DC/DC-Converter
Specifications - Continued
Typical Characteristics
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
2405
1205
0505
3.305
Deviation / Load
-10.000
40%0% 100%
Deviation from Nominal (%)
60%
80%
20%
-5.000
Total Output current (%)
0505
0.000
5.000
10.000
15.000
20.000
25.000
1205
2405
3.305
R2S-xx05
Isolation Voltage (tested for 1 second) 1000VDC
(rated for 1 minute***) 500VAC / 60Hz
Isolation Voltage (tested for 1 second) 3000VDC
(rated for 1 minute***) 1500VAC / 60Hz
Isolation Capacitance 115pF max.
Isolation Resistance (Viso 500V) 10 GΩ min.
Short Circuit Protection 1 Second
P-Suffix Continuous
Operating Temperature Range (free air convection) -40°C to +100°C (see Graph)
Storage Temperature Range -55°C to +125°C
Reflow Temperature ROHS compliant 245°C (30 sec), peak 255°C (5 sec) max.
Vapor Phase Process (for more details see Application Notes) 230°C (90 sec) max.
Relative Humidity 95% RH
Package Weight R2S, R2S8 1.4g
R2D, R2D10 1.5g
R2S12, R2D12 1.6g
Packing Quantity R2S, R2S8 39 pcs per Tube
R2S12, R2D, R2D10, R2D12 33 pcs per tube
All Types 250 pcs per Reel
MTBF (+25°C) using MIL-HDBK 217F 886 x 10
3
hours
(+85°C) using MIL-HDBK 217F 128 x 10
3
hours
Certifications
CB Test Report Report: US/14402/UL
UL General Safety Report: E358085 UL 60950-1 2nd Ed.
CUL General Safety C22.2 No. 60950-1-03
EN Medical Safety Report: MDD1205098-2 + RM1205098-2 IEC/EN 60601-1 3rd Ed.
Medical Report + ISO14971 Risk Assessment
EN General Safety Report: SPCLVD 1211033-3 EN60950-1: 2006 + A12:2011
Conducted / Radiated Emissions EN55022 Level A
}
Detailed Information see
Application Notes chapter "MTBF"
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
2405
1205
0505
3.305
Deviation / Load
-10.000
40%0% 100%
Deviation from Nominal (%)
60%
80%
20%
-5.000
Total Output current (%)
0505
0.000
5.000
10.000
15.000
20.000
25.000
1205
2405
3.305
R2D-xx05
Notes
Note 1 Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter.