Datasheet
www.recom-power.com
REV.: 1/2018 PA-3
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RAC04-C/W
Series
ENVIRONMENTAL
Parameter Condition
Value
Operating Temperature Range @ natural convection 0.1m/s
full load -25°C to +60°C
refer to derating graph -25°C to +85°C
Maximum Case Temperature +100°C
Operating Humidity non-condensing 95% RH max.
MTBF according to MIL-HDBK-217F, G.B.
115VAC
230VAC
+25°C
820 x 10
3
hours
735 x 10
3
hours
115VAC
230VAC
+60°C
550 x 10
3
hours
430 x 10
3
hours
-25 -20 0 20 40 60 80 100
100
80
60
40
90
70
50
30
20
10
0
Output Load [%]
Ambient Temperature [°C]
75
25
70 85
100
80
60
40
90
70
50
30
20
10
0
Output Load [%]
Input Voltage [VAC]
80 130 180 230 280
85
90 264
Derating Graph
(@ Chamber and natural convection 0.1m/s)
Line Derating
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report / File Number
Standard
Information Technology Equipment - General Requirments for Safety SPCLVD1606038
IEC60950-1:2005 2nd Edition + 2:2013
EN60950-1:2006 + A2:2013
Information Technology Equipment - General Requirments for Safety E224736-A5-UL
CAN/CSA-C22.2 No. 60950-1-07, 2nd Edition, 2007
UL No. 60950-1, 2nd Edition, 2007
EAC Safety of Low Voltage Equipment RU-AT.49.09571 TP TC 004/2011
RoHS2+ RoHS-2011/65/EU + AM-2015/863
EMC Compliance Condition Standard / Criterion
Electromagnetic compatibility of multimedia equipment – Emission Requirements
EN55032:2015, Class B
Information technology equipment - Immunity characteristics - Limits and
methods of measurement
EN55024:2010 + A1:2015
ESD Electrostatic discharge immunity test Air ±8.0kV, Contact ±4.0kV IEC61000-4-2:2008, Criteria A
Radiated, radio-frequency, electromagnetic field immunity test 3V/m IEC61000-4-3:2006 + A2:2010, Criteria A
Fast Transient and Burst Immunity AC Power Port: ±1.0kV IEC61000-4-4:2012, Criteria A
Surge Immunity AC Power Port: L-N ±1.0kV IEC61000-4-5:2005, Criteria A
Immunity to conducted disturbances, induced by radio-frequency fields AC Power Port 3.0V IEC61000-4-6:2008, Criteria A
Voltage Dips and Interruptions
Voltage Dips >95%
Voltage Dips 30%
Voltage Interruptions > 95%
IEC61000-4-11:2004, Criteria A
IEC61000-4-11:2004, Criteria A
IEC61000-4-11:2004, Criteria C
Limits of Voltage Fluctuations & Flicker EN61000-3-3:2013