Datasheet

AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, rated load and after warm-up unless otherwise stated)
RACD03
Series
www.recom-power.com
REV.: 3/2019 L-2
ENVIRONMENTAL
Parameter
Condition
Value
Operating Temperature Range
according to UL
according to ENEC
-20°C to +50°C
-20°C to +40°C
Max. Case Temperature
according to UL
according to ENEC
RACD03-350, RACD03-700
RACD03-500
+67°C
+65°C
+75°C
IP Rating IP66
Operating Humidity non condensing 5% - 85% RH max.
Design Lifetime +25°C ambient 20 x 10
3
hours
continued on next page
PROTECTION
Parameter
Condition
Value
Input Fuse
(2)
T1A, slow blow
Short Circuit Protection (SCP)
continuous, current limit
Overload Protection (OLP)
120% typ.
Output Over Voltage Protection (OVP) zener diode clamp
RACD03-350
RACD03-500
RACD03-700
17VDC max.
14VDC max.
8VDC max.
Over Temperature Protection (OTP) shutdown, automatic resatart after cooling down
Isolation Voltage I/P to O/P 3.75kVAC/1 minute typ. / 3kVAC/1 minute min.
Leakage Current 0.2mA typ.
Maximum loading of automatic circuit breakers*
Circuit Breaker Circuit Breaker Current
Typ 10A 16A 20A 25A
C 221 247 337 430
Circuit Breaker Circuit Breaker Current
Typ 10A 16A 20A 25A
B 80 157 200 254
C 265 317 437 550
* @ 115VAC, 1Ohm, 90° phase angle and max. load * @ 230VAC, 1Ohm, 90° phase angle and max. load
Notes:
Note2: Refer to local wiring regulations if input over-current protection is also required
Constant Current (CC) and Constant Voltage (CV)
(1)
CV
CCCC
CV
CC
RACD03-350
RACD03-500
RACD03-700
Nominal Current Limits
Output Current
Output Voltage
500mA
700mA
600mA
350mA
300mA
0mA
3V
6V
4.5V
9.5V
15V
12V
Notes:
Note1: CV Mode is approved by Recom internal quality standard, but not certified