DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load otherwise stated)
RE
Series
Parameter Condition Value
Load Regulation
(5)
10% to 100% load
3.3Vout
5Vout
9, 12, 15, 24Vout
20.0% max.
15.0% max.
10.0% max.
Deviation vs. Load
25
15
5
-5
20
10
0
-10
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
3.305
0505
1205
25
15
5
-5
20
10
0
-10
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
3.312
0512
1212
25
15
5
-5
20
10
0
-10
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
3.315
0515
1215
RE-xx05S RE-xx12S
PROTECTIONS
Parameter Type Value
Short Circuit Protection (SCP)
without suffix
with suffix “/P”
1 second
continuous
Isolation Voltage
(6)
I/P to O/P
without suffix
tested for 1 second
rated for 1 minute
1kVDC
500VAC/60Hz
with suffix
“/H”
tested for 1 second
rated for 1 minute
2kVDC
1kVAC/60Hz
Isolation Resistance 10G min.
Isolation Capacitance 20pF min. / 75pF max.
Insulation Grade
basic (IEC/EN60950-1)
functional (UL60950-1)
RE-xx15S
Notes:
Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note7: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type
Notes:
Note5: Operation below 10% load will not harm the converter, but specifications may not be met