Datasheet
3
1
2
5
4
20.32
50.8
dia.
0.8
10.16
10.16
12.70
15.24
Bottom View
6
2.50
5.08
25.4
5.6
10.2
20.32
15.2
2.54
5.08
REC10/M
Specifications cont. (measured at T
A
= 25°C, nominal input voltage, full load and after warm-up)
Isolation Voltage H2-Suffix (tested for 1 second) 2000VDC
(rated for 1 minute) 1000VAC / 60Hz
H3-Suffix (tested for 1 second) 3000VDC
(rated for 1 minute) 1500VAC / 60Hz
Under Voltage Lockout (2:1) 12V Input DC-DC on 8.3VDC, DC-DC off 7.9VDC
24V Input DC-DC on 17.4VDC, DC-DC off 16.7VDC
48V Input DC-DC on 35.7VDC, DC-DC off 34.3VDC
Under Voltage Lockout (4:1) 24V Input DC-DC on 8.3VDC, DC-DC off 7.9VDC
48V Input DC-DC on 17.4VDC, DC-DC off 16.7VDC
Isolation Capacitance 1200pF typ.
Isolation Resistance 1 GΩ min.
Overload Protection 150% typ.
Short Circuit Protection Continuous, Auto Restart
Operating Temperature Range 4:1 -40°C to +71°C (see Graph)
(free air convection) 2:1 -40°C to +81°C (see Graph)
Storage Temperature Range -55°C to +105°C
Remote On/Off DC/DC ON Open or 3.5V<Vr<12V
DC/DC OFF Short or 0V<Vr<1.2V
Temperature Coefficient ±0.05% max.
Relative Humidity 95% RH
Case Material Nickel Plated Metal with Non-Conductive Base
Thermal Impedance Natural convection 12°C/W
Maximum Case Temperature 100°C
Vibration 10-55Hz, 2G, 30mins along X,Y & Z
Package Weight 27g
Packing Quantity 10 pcs per Tube
MTBF (+25°C) using MIL-HDBK 217F >1000 x 10
3
hours
(+71°C) using MIL-HDBK 217F >250 x 10
3
hours
Certifications
EN General Safety Report: SPCLVD1211033-2 EN60950-1:2006 + A12:2011
UL General Safety Report: E224736 UL 60950-1 1st Ed.
C22.2 No. 60950-1-03
EN Medical Safety Report: MDD12060585 + RM1206085
IEC/EN 60601-1 3rd Edition; Medical Report + ISO14971 Risk Assessment
REC10-S_D/H*/M
Series
ECONOLINE
DC/DC-Converter
Derating-Graph
(Ambient Temperature)
2:1 Converters
4:1 Converters
Package Style and Pinning (mm)
2” x 1” Package
XX.X ± 0.5 mm
XX.XX ± 0.35 mm
Pin Connections
Pin # Single Dual
1 +Vin +Vin
2 –Vin –Vin
3 +Vout +Vout
4 No Pin Com
5 –Vout –Vout
6 CTRL CTRL
Detailed Information see
Application Notes chapter "MTBF"
}
Note: Refer to Application Notes for EMC Class B Filter suggestion
Output Power (%)
100
60
20
40
100
500-40 150
Operating Temperature °C
0
80
Safe Operating Area
81
Output Power (%)
100
60
20
40
90
50
0-40
71
150
Operating Temperature °C
0
80
Safe Operating Area
4:1
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
REV: 0/2015 E-167www.recom-power.com