Datasheet

www.recom-power.com
REV.: 8/2019 PDR-4
AC/DC Converter
Specifications (measured at
Ta
= 25°C, 230VAC, full load and after warm up)
REDIN45
Series
DIMENSION and PHYSICAL CHARACTERISTICS
Parameter Type Value
Material case plastic, (UL94V-0)
Dimension (WxHxD) 45.1 x 92.0 x 101.2mm
Weight 332g
continued on next page
7.5±0.2
101.2
92.0
45.1
75±0.3
35±0.1
DIN-RAIL mounting bracket
(75mm) included
SIDE MOUNTINGEND MOUNTING
18±0.2
1±0.05
25.0
25.0
6.3±0.2
Side Latch
Release
End Latch
Release
Front Side
Front Side
DC OK
DC OK
DC OK
TRIM
Tolerance: ±0.5mm
FG N L
+V -V
FG N L
+V -V
Dimension Drawing (mm)
SAFETY AND CERTIFICATIONS
Certificate Type (Safety) Report / File Number Standard
Information Technology Equipment - General Requirments for Safety
E224736-A23
UL60950-1 2nd Edition 2011
CAN/CSA-C22.2 No. 60950-1-07 2nd Edition 2011
Industrial Control Equipment E470721
CAN/CSA-C22.2 No. 107.1-01, 3rd Edition 2011
UL508, 17th Edition 2013
Information Technology Equipment - General Requirments for Safety
E224736-A23
EN60950-1:2006 + A2:2013
IEC60950-1:2005 2nd Edition + A1:2009
EAC RU-AT.37.02367 TP TC 004/2011
RoHS2 RoHs 2011/65/EU
EMC Compliance Report / Condition Standard / Criterion
Electromagnetic compatibility of multimedia equipment – Emission
Requirements
EN55032:2015
Information technology equipment - Immunity characteristics -
Limits and methods of measurement
EN55024:2010 + A1:2015
ESD Electrostatic discharge immunity test Air +/-2, 4, 8kV, Contact +/-2, 4kV IEC61000-4-2:2008; Criteria A
Radiated, radio-frequency, electromagnetic field immunity test 3V/m IEC61000-4-3:2006 + A1:2007 + A2:2010; Criteria A
Fast Transient and Burst Immunity AC Power Port: +/-1.0kV IEC61000-4-4:2012; Criteria A
Surge Immunity
AC Power Port: L-N +/-0.5, 1, 2kV
L-PE, N-PE +/-0.5, 1, 2, 4kV
IEC61000-4-5:2014; Criteria A
Immunity to conducted disturbances, induced by radio-frequenc
y fields AC Power Port 3V IEC61000-4-6:2013; Criteria A
Power Magnetic Field Immunity 50Hz, 1A/m IEC61000-4-8:2009; Criteria A
Voltage Dips and Interruptions
Voltage Dips >95%
Voltage Dips 30%
Voltage Interruptions > 95%
IEC61000-4-11:2004; Criteria A
IEC61000-4-11:2004; Criteria A
IEC61000-4-11:2004; Criteria B
Limits of Harmonic Current Emissions EN61000-3-2:2014, Class A
Limits of Voltage Fluctuations & Flicker EN61000-3-3:2013
Limitations on the amount of electromagnetic interference allowed
from digital and electronic devices
47 CFR FCC Part 15 Subpart B 2010-01-07, Class B