Datasheet

www.recom-power.com
REV.: 1/2019 L-3
AC/DC Converter
Specifications (measured @ Ta= 25°C and 230VAC)
RELV4-16
Series
DIMENSION and PHYSICAL CHARACTERISTICS
Parameter Type
Value
Material
PCB
case
plastic resin with fibreglass, (UL94 V-0)
plastic, (UL94 V-2)
Dimension (LxWxH) 112.0 x 42.0 x 24.0mm
Weight 80g typ.
AC N
AC L
42.0
FC 30.0
FC 100.0
24.0
112.0
17.0
57.0
tc
LED
DA+
DA -
Dimension Drawing (mm)
EMC Compliance
Conditions
Standard / Criterion
Limits and methods of measurement of radio disturbance characteristics of electrical
lighting and similar equipment
EN55015:2013 + A1:2015
Limitations on the amount of electromagnetic interference allowed from digital and
electronic devices
FCC 47 CFR Part 15
Equipment for general lighting purposes – EMC immunity requirements
EN61547:2009
ESD Electrostatic discharge immunity test
Air ±2, ±4, ±8kV
Contact ±2, ±4kV
IEC61000-4-2:2008, Criteria A
Radiated, radio-frequency, electromagnetic field immunity test
3V/m (80-1000MHz) IEC61000-4-3:2006, Criteria A
Fast Transient and Burst Immunity
AC Power Port: ±0.5kV IEC61000-4-4:2012, Criteria A
Surge Immunity
AC Power Port: L-N ±0.5kV, ±1kV IEC61000-4-5:2005, Criteria A
Immunity to conducted disturbances, induced by radio-frequency fields
AC Power Port: 3V IEC61000-4-6:2008, Criteria A
Power Magnetic Field Immunity
50, 60Hz, 3A/m IEC61000-4-8:2009, Criteria A
Voltage Dips and Interruptions
Voltage Dips 30%
IEC61000-4-11:2004, Criteria B
Voltage Dips and Interruptions
Voltage Interruptions >95%
IEC61000-4-11:2004, Criteria B
Limits of Harmonic Current Emissions
EN61000-3-2:2014
Limits of Voltage Fluctuations & Flicker
EN61000-3-3:2013
Screw Terminal Information
Function Wire Diameter AWG
AC N 0.5-1.5mm² 14~26
AC L 0.5-1.5mm² 14~26
DA+ 0.5-1.5mm² 14~26
DA- 0.5-1.5mm² 14~26
wire stripping length: 5~6mm
tc= case temperature measuring point
FC= fixing centers
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.35mm
2 mounting screws are included