Datasheet
DC/DC Converter
ECO-2
REV.: 2/2016 www.recom-power.com
Specifications (measured at T
A
= 25°C, nominal input voltage, full load and after warm up unless otherwise specified)
PROTECTIONS
Parameter Condition Value
Input Filter Internal Capacitor
Short Circuit Protection (SCP) continuous
Isolation Voltage
I/P to O/P, tested
I/P to O/P, rated
6.4kVDC / 1 Second
5.2kVDC / 1 Minute
Isolation Capacitance 75pF max.
Isolation Resistance 10GΩ min.
REGULATIONS
Parameter Condition Values
Output Voltage Accuracy full load, nom. Vin ±5% max.
Line Voltage Regulation low line to high line, max. load ±1.2% / 1%Vin typ.
Load Voltage Regulation 10% to 100% load 10% max.
RK/H6 & RH/H6
Series
0 10
-5
0
5
10
15
20 30 40 50 60 70 80 90 100
RK-123.3S/H6
RK-0505S/H6
RK-0512S/H6
RK-2415S/H6
Load (%)
Deviation (%)
RH-123.3D/H6
RH-0505D/H6
RH-1212D/H6
RH-0515D/H6
0 10
-5
0
5
10
15
20 30 40 50 60 70 80 90 100
Load (%)
Deviation (%)
Deviation vs. Load
Single Output Dual Output
Efficiency vs. Load
0
0
10
10
20
20
30
30
40
40
50
50
60
60
70
70
80
80
90
90
100
100
RK-123.3S/H6
RK-0505S/H6
RK-0512S/H6
RK-2415S_H6
Load (%)
Efficiency (%)
0
0
10
10
20
20
30
30
40
40
50
50
60
60
70
70
80
80
90
90
100
100
RH-123.3D/H6
RH-0505D/H6
RH-1212D/H6
RH-0515D/H6
Load (%)
Efficiency (%)
Single Output Dual Output