Datasheet

Detailed Information see
Application Notes chapter "MTBF"
Input Voltage Range ±10%
Output Voltage Accuracy ±5%
Line Voltage Regulation 1.2%/1% of Vin typ.
Load Voltage Regulation 3.3V output types 20% max.
(10% to 100% full load) 5V output type 15% max.
12V, 15V, 24V output types 10% max.
Output Ripple and Noise (20MHz limited) 50mVp-p max.
Operating Frequency 50kHz min. / 90kHz typ. / 105kHz max.
Efficiency at Full Load 65% min. / 75% typ.
Minimum Load = 0% Specifications valid for 10% minimum load only.
Isolation Voltage (tested for 1 second) 1000VDC
(rated for 1 minute**) 500VAC / 60Hz
Isolation Voltage H-Suffix (tested for 1 second) 2000VDC
H-Suffix (rated for 1 minute**) 1400VAC / 60Hz
Isolation Capacitance 25pF min. / 82pF max.
Isolation Resistance 10 GΩ min.
Short Circuit Protection 1 Second
P-Suffix Continuous
Operating Temperature Range (free air convection) -40°C to +85°C (see Graph)
Storage Temperature Range -55°C to +125°C
Relative Humidity 95% RH
Package Weight RM types 1.4g
RL types 1.8g
Packing Quantity 42 pcs per Tube
MTBF (+25°C) using MIL-HDBK 217F 1327 x 10
3
hours
(+85°C) using MIL-HDBK 217F 302 x 10
3
hours
contiued on the next page
Refer to Application Notes
0.25 Watt
SIP4
Single Output
Single Output Rail
Industry Standard Pinout
1kVDC or 2kVDC Isolation
High Efficiency for Low Power Applications
UL94V-0 Package Material
Optional Continuous Short Circuit Protected
Fully Encapsulated
Custom versions available
Efficiency to 76%
Features
Unregulated
Converter
Selection Guide
Specifications (measured at T
A
= 25°C, nominal input voltage, full load and after warm-up)
}
Derating-Graph
(Ambient Temperature)
Output Power (%)
100
60
20
40
100500-40
85
150
Operating Temperature °C
0
80
Safe Operating Area
30
Description
The RM series DC/DC converter has been designed for isolating or converting DC power
rails with very light loads. Efficiencies are typically 10% higher than a comparable 0.5W or
1W converters run at the same low load.
Part Input Output Output Efficiency Max.
Number Voltage Voltage Current Capacitive
SIP 4 (2kV) (VDC) (VDC) (mA) (%) Load
(1)
RM-xx3.3S (H) 3.3, 5, 12, 15, 24 3.3 76 65-70 1000µF
RM-xx05S (H) 3.3, 5, 12, 15, 24 5 50 66-72 470µF
RM-xx09S (H) 3.3, 5, 12, 15, 24 9 28 70-72 470µF
RM-xx12S (H) 3.3, 5, 12, 15, 24 12 21 70-72 150µF
RM-xx15S (H) 3.3, 5, 12, 15, 24 15 17 70-76 150µF
xx = Input Voltage (other input and output voltage combinations and output powers available on request)
* add Suffix “P” for Continuous Short Circuit Protection, e.g.
RM-0505S/P, RM-0505S/HP
EN-60950-1 Certified
UL-60950-1 Certified
IEC/EN-60601-1 Certified*
* (/H suffix)
RM
ECONOLINE
DC/DC-Converter
with 3 year Warranty
REV: 0/2015 www.recom-power.comE-2
RoHS
2011/65/EU
6/6
E358085
**Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer to our Application Notes.