Datasheet

+
Output
C1
Input
470pF/4kVDC
GND
DC
DC
GND
Fuse
Deviation / Load
-10
40%0% 100%
Deviation from Nominal (%)
60%
80%
20%
-5
Total Output current (%)
0
5
10
15
20
25
0505
2405
1205
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
0505
2405
1205
+10%
+5%
V Nom.
+5%
 1%
10% 50% 100%
Output Voltage
Output Load Current (%)
 5%
Typical Load Line
RTM Series
ECONOLINE
DC/DC-Converter
RTM-xx05S
Typical Characteristics
RTM
Tolerance Envelope
Package Style and Pinning
Pin Connections
Pin # Function
1 +Vin
2 -Vin
12 -Vout
13 +Vout
14~17 NC
27,28 NC
NC = No Connection
Unit: mm
Tolerance: ± 0.25 mm
EMC Filtering - Suggestion for EN55022 Class B
Input Inductance/
Voltage Capacitance (C1)
5V 4.7µF
12V 2.2µF
24V 47µF
RECOM
RTM-xx05S
Pb
9.00
28 27 17 16 15
1 2 12 13 14
4.05 max.
1.27x13
18.00
7.15
8.70
10.65
0.90
TOP VIEW
1.27
13*1.27= 16.51
1.40
11.80
Recommended Footprint Details
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
REV: 0/2015 www.recom-power.comE-84