Datasheet
RV /R
ECONOLINE
DC/DC-Converter
Relative Humidity 95% RH
Package Weight 9g
Packing Quantity 15 pcs per Tube
MTBF (+25°C) using MIL-HDBK 217F 1154 x 10
3
hours
(+85°C) using MIL-HDBK 217F 168 x 10
3
hours
Reinforced Isolation Transformer Creepage Reinforced Types 5.5 mm min.
Transformer Clearance Reinforced Types 5.5 mm min.
PCB Creepage & Clearance Reinforced Types 4.8 mm min.
Certifications
Measurement, Control and Laboratory Use Safety Report: T1301251-313 EN 61010-1 : 2010
CSA General Safety UL 60950-1 1st Edition
C22.2 No. 60950-1-03
UL/cUL Medical Safety Report: E314885-A4 UL60601-1 3rd Edition
CSA Medical Safety Report: 2207629 CAN/CSA-22.2 No 601.1-M90
EN General Safety Report: SPCLVD1310079-1 EN60950-1 : 2006
EN Medical Safety Report: CA-10168-A1-UL IEC/EN 60601-1 3rd Edition
Specifications (measured at T
A
= 25°C, nominal input voltage, full load and after warm-up)
Tolerance Envelope
+10%
+6%
V Nom.
+5%
2.5%
10% 50% 100%
Output Voltage
Output Load Current (%)
5%
Typical Load Line
}
Detailed Information see
Application Notes chapter "MTBF"
Notes
Note 1 Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter.
RV/R
Series
REV: 1/2015 www.recom-power.comE-114