Original Instruction Manual AC400 Air Cleaner Version 3.0 November 2012 To register this product please visit www.recordpower.info It is important to register your product as soon as possible in order to receive efficient after sales support and be entitled to the full 5 year guarantee. Your statutory rights are not affected. Please see back cover for contact details. Kg i Always wear safety glasses when using woodworking equipment.
Contents 1 Explanation of Symbols 2 General Health & Safety Guidance 3 Additional Health & Safety Guidance for the AC400 Air Cleaner 4 Record Power Guarantee 5 Specifications 6 Unpacking & Checking Contents 7 Assembly 8 Operation 9 Electrical Connection & Wiring Diagram 10 Parts Lists & Diagrams EU Certificate of Conformity 2 Original Instruction Manual | AC400 Air Cleaner | Version 3.
Explanation of Symbols THE SYMBOLS AND THEIR MEANINGS SHOWN BELOW MAY BE USED THROUGHOUT THIS MANUAL. PLEASE ENSURE THAT YOU TAKE THE APPROPRIATE ACTION WHEREVER THE WARNINGS ARE USED. Mandatory Instructions i Read and fully understand the instruction manual before attempting to use the machine.
General Health & Safety Guidance Ensure that you carefully read and fully understand the instructions in this manual before assembly, installation and use of this product. Keep these instructions in a safe place for future reference. WARNING: for your own safety, do not attempt to operate this machine until it is completely assembled and installed according to these instructions.
General Health & Safety Guidance 7. Remove adjusting keys and wrenches • Ensure that all adjusting wrenches and keys are removed before switching the machine ‘ON’. There is a risk of severe personal injury or damage to the machine from airborne objects. 8. Before switching the machine ‘ON’ • Clear the machine table of all objects (tools, scrap pieces etc.) • Make sure there is no debris between the work piece and the table / work support. the presence of flammable liquids, gases or dust.
General Health & Safety Guidance 16. Avoid unintentional starting of the machine • Most machines are fitted with a no-volt release (NVR) switch to prevent unintentional starting. If in doubt always ensure the machine switch is in the ‘OFF’ position before connecting it to the power supply. This means the machine will not automatically start up after a power cut or switching on of the power supply, unless you first reset the start switch. 17. Outdoor use • Your machine should not be used outdoors. 18.
General Health & Safety Guidance • Remember always to switch off and unplug the machine from the power supply before carrying out any setting up or maintenance operations. • Follow any instructions for the maintenance of accessories and consumables. • Do not use compressed air to clean the machine. Always use a brush to dislodge dust in places that are awkward to reach and a dust extractor to collect the waste.
2. Additional Health & Safety Guidance for the AC400 Air Cleaner 1. General Guidance • Do not use the Air Filtration System for anything except wood dust. Materials such as liquids, metal shavings, metal dust, screws, glass, plastic or rock can cause sparks and/or damage when coming into contact with any part of the machine. • If ceiling mounted, mounts must be anchored to building structure which will support a minimum of 45 kg. Never mount to surfaces such as dry wall or false ceiling grids, etc.
Record Power Guarantee 1.2.8 the Product has been purchased by you as the guarantee is not transferable from a private sale. 1.2.9 where the Product has been purchased from a retailer, the 5 year guarantee is transferable and begins on the date of the first purchase of the Product and in the event of a claim under this guarantee proof of the original purchase date will be required to validate the warranty period. 2 Claims Procedure 2.
5. Specifications 10 Outer Filter: 5 Microns Inner Filter: 1 Micron Overall Dimensions: L514 x W431 x H258 mm Sound Rating @ 1 m: High Speed 69 dB Medium Speed 67 dB Low Speed 62 dB Air Flow: High Speed 409 CFM Medium Speed 362 CFM Low Speed 260 CFM Motor: 230V / 50Hz 1/8 hp / 100 W Full load current: 0.43 A Timer Settings: 1, 2 and 4 hours Weight: 14 kg Original Instruction Manual | AC400 Air Cleaner | Version 3.
6.
7. Assembly • If you notice any transport damage while unpacking, notify the supplier immediately. B C • Dispose of the packing in an environmentally friendly manner. You should take into consideration how and where you will place the unit: • It can be placed on a bench or be hung from the ceiling. • This unit will work best if it is located away from corners, and heating/cooling vents. • If using on sawhorses the air filtration unit should be clamped in place.
8. Operation Controls & Features Remote Control Time button (Fig 3) controls the three different timer settings. 1hr will light up on the back of the unit by pressing the time button once. The machine will operate for 1 hour then turn off. 2hr will light up on the back of the unit by pressing the time button twice. The machine will operate for 2 hours then turn off. 4hr will light up on the back of the unit by pressing the time button three times. The machine will operate for 4 hours then turn off.
8. Operation Changing the Filters • There are two filters that need to be cleaned and / or changed. The outer filter can easily be removed by disengaging the two clips (Fig 5). • Once the outer filter is removed the inner filter can now be pulled out of the unit (Fig 6). The inner filter can be blown out with air or washed out. The filter should be completely dry before reinstalling into the machine.
9. Electrical Connection & Wiring Diagram Machines supplied for use in the UK are fitted with a 3 pin plug conforming to BS1363, fitted with a fuse conforming to BS1362 and appropriate to the current rating of the machine. Machines supplied for use in other countries within the European Union are fitted with a 2 pin Schuko plug conforming to CEE 7/7. Machines supplied for use in Australia & New Zealand are fitted with a 3 pin plug conforming to AS/NZS3112.
10. Parts Lists & Diagrams 16 Original Instruction Manual | AC400 Air Cleaner | Version 3.
10. Parts Lists & Diagrams No. Part Name Quantity No.
EU Declaration of Conformity Cert No: EU / AC400 / 1 Record Power Ltd Unit B, Ireland Industrial Estate, Adelphi Way, Staveley, Chesterfield, Derbyshire S43 3LS declares that the machinery described:Air Cleaner 1. Type: 2. Model No: AC400 3. Serial No .........................................................................
Woodworking Machinery & Accessories United Kingdom Eire Australia New Zealand Record Power Ltd Record Power Ltd Tools 4 Industry Tools 4 Industry Unit B Adelphi Way, Ireland Industrial Estate, Staveley, Chesterfield, Derbyshire S43 3LS Unit B Adelphi Way, Ireland Industrial Estate, Staveley, Chesterfield, Derbyshire S43 3LS Po Box 3844 Parramatta 2124 Po Box 276079 Manukau City 2241 Tel: 01246 561 520 www.recordpower.co.uk Tel: 01246 561 520 www.recordpower.co.